OPEN input
[Kl.16]
OPEN input
[Kl.18]
0V / Earth
•
Input for push-button, key-operated push-button, external radio, etc.
•
NO contact, floating
•
Several control sensors can be connected
in parallel
.
•
With [M.b3] = "dead-man function", radio operation for the corresponding direc-
tion of travel is disabled.
•
The door stops when the OPEN and CLOSE inputs are simultaneously actuated.
Further running direction commands (radio, pulse, membrane keypad) are not
executed.
•
When the advance warning time is set [M.A9], the door start is delayed.
CLOSE input
[Kl.17]
CLOSE input
[Kl.18]
0V / Earth
•
Input for push-button, key-operated push-button, external radio, etc.
•
NO contact, floating
•
Several control sensors can be connected
in parallel
.
•
The function of the input is set in [M.b4]
•
With [M.b4] = "dead-man function", radio operation for the corresponding direc-
tion of travel is disabled.
•
The door stops when the OPEN and CLOSE inputs are simultaneously actuated.
Further running direction commands (radio, pulse, membrane keypad) are not
executed.
•
When the advance warning time is set [M.b0], the door start is delayed.