Operator controls & functions/displays

Explanation of abbreviations

Abbreviation

Description

USA 

Bottom rail sensor; sensor of main closing edge safety device. De-
tects obstructions when the door is lowering

LS 

Light barrier; for use in buildings as monitoring device for door sys-
tem and to control the automatic reclosing operation.

AWZ

Automatic reclosing; the door lowers automatically after the set re-
closing time.

M

Drive

[Ta.+]

"+" on the PCB

[Ta.-]

"-" on the PCB

[Ta.F]

"Radio" button on the PCB

[Ta.M]

"Menu" button on the PCB

SE1

Safety input 1

SE2

Safety input 2

[Kl.1]..[Kl.25]

Reference to connecting terminals

[M.A0]..

[M.C9]

Menu table "Setting a function", menu items "A0" to "C9"

[Er.01]..

[Er.25]

Error message, shown in the display

[F1]..[F2]

Radio module function, shown in the display

10

Summary of Contents for Beck-O-Tronic 6

Page 1: ...Door control unit Important information for Fitters Electricians Users Please forward accordingly These instructions must be kept safe for future reference Becker Antriebe GmbH Friedrich Ebert Stra e...

Page 2: ...metrisation 15 Menu table 16 Connections functions 22 Reset factory setting 29 Functional description 30 Remote control 34 Disposal 36 Maintenance 36 Cleaning 37 Error messages 37 Complete connecting...

Page 3: ...res that must be taken to avoid damage to property Denotes user tips and other useful information Warranty Structural modifications and incorrect installation which are not in accordance with these an...

Page 4: ...3 safety in use of power operated doors re quirements EN 12445 safety in use of power operated doors testing methods EN 12978 safety devices for power operated doors requirements and testing methods E...

Page 5: ...ssembly and Operat ing Instructions Before working on the control unit it must be discon nected from the power supply and measures must be taken to ensure it cannot be inadvertently switched back on F...

Page 6: ...tching function and or sun protection function For travel in the DOWN direction in maintained operation a closing edge safety device is necessary This type of control unit must not be used in potentia...

Page 7: ...Product overview Status display OPEN button STOP button CLOSE button Hand held transmitter Mains plug Caution Work on the electrical equipment may only be carried out by a qualified electrician 7...

Page 8: ...t direct solar radiation and driving rain Open the cover of the control unit Pull the cable from the cover off and carefully place the cover to one side Remove the required cut outs in the bottom part...

Page 9: ...connection or lockable main switch The control unit is protected by a 5 AT 5 x 20 mm fuse loc ated below the shock hazard protection cover Switch the operating voltage off before replacement First pul...

Page 10: ...s tem and to control the automatic reclosing operation AWZ Automatic reclosing the door lowers automatically after the set re closing time M Drive Ta on the PCB Ta on the PCB Ta F Radio button on the...

Page 11: ...ings Ta M Menu button Menu selection display of input status Display on left Door status Display on left Segment status Door status Lit In the CLOSE limit position Lit Permanently in the CLOSE limit p...

Page 12: ...warning time running Lit Automatic reclosing Stay open time run ning Flashes Stay open time after exiting light barrier running Display on right Status of inputs Display on right Segment status Input...

Page 13: ...y open Automatic reclosing ex ternal inputs and radio dis abled STOP Drive operation in pro gress STOP If the drive is at a standstill Light on off if light function is set with overrun time Steady li...

Page 14: ...redundancy On Flashes Flashes Flashes Control unit defective replacement neces sary On On On Error negative testing pre limit switch pos sibly too high On Flashes Error Running time ex ceeded On Flash...

Page 15: ...vel 1 highest level selection of menu item or function Level 2 lowest level selection of menu values setting values Parameter editing Display 1 Control unit in door status display Display of current d...

Page 16: ...MITATION 00 90 Maximum drive running time 1 90 s in 1 s incre ments 60 91 99 Maximum drive running time 1 9 min in 1 min in crements A1 LIMIT POSITION DETECTION 00 Running time without drive current m...

Page 17: ...fect Stop 05 Stop Stop 06 Reverse travel Stop 06 07 Reopening Stop 08 No effect Reverse travel 09 Stop Reverse travel 10 Reverse travel Reverse travel 11 Reopening Reverse travel 12 No effect Reclosin...

Page 18: ...o effect Reverse travel 09 Stop Reverse travel 10 Reverse travel Reverse travel 11 Reopening Reverse travel 12 No effect Reclosing 13 Stop Reclosing 14 Reverse travel Reclosing 15 Reopening Reclosing...

Page 19: ...e g red traffic light Off 5 s after CLOSE limit position 65 Only during advance warning time and motor oper ation 1 Hz flashing A9 ADVANCE WARNING TIME PRIOR TO TRAVEL IN THE OPEN DIRECTION 00 Off 00...

Page 20: ...mit switch b6 SLAT ADJUSTMENT 00 Operation without slat adjustment 00 01 Operation with slat adjustment A short command 1 s via pulse OPEN CLOSE or radio effects a slat adjustment A long command 1 s v...

Page 21: ...1 Menu items not adjustable Changeover Press EMERGENCY STOP Ta and Ta simul taneously Toggle between 00 and 01 with Ta M C8 Version number only readable Display of 8 digit version number by running a...

Page 22: ...peration and following a drive operation for the selected time With the setting 04 to 60 the light goes out briefly once 10 s before the time expires and signals the pending time rundown With M A8 61...

Page 23: ...removed when it is in use The automatic reclosing function after an EMERGENCY STOP is adjusted in M b2 The EMERGENCY STOP input switches the drive and light relay off directly and is therefore still e...

Page 24: ...for SE1 and M A5 for SE2 Setting the function of the safety input for travel in the OPEN direction and travel in the CLOSE direction Stop Drive remains at standstill Reverse travel When approaching a...

Page 25: ...re wave safety edge DW edge is used its function must be tested An external pre limit switch is needed for this The pre limit switch is only effective in combination with the safety input SE1 and is a...

Page 26: ...2 02 Kl 12 LS transmitter 12V Kl 18 or Kl 20 Earth Kl 11 LS receiver 12V Kl 13 and Kl 14 Relay output LS During the self test of the control unit the 12 V Kl 12 to the LS transmitter is briefly interr...

Page 27: ...ector output cannot be used The connection is established according to item Safety input SE1 LS 1k2 8K2 OSE or Safety input SE2 LS 1k2 8K2 OSE When the automatic reclosing is active and the LS input i...

Page 28: ...executed When the advance warning time is set M A9 the door start is delayed CLOSE input Kl 17 CLOSE input Kl 18 0V Earth Input for push button key operated push button external radio etc NO contact f...

Page 29: ...h Kl 21 Pre limit switch signal input Kl 20 0V Earth When the safety input SE1 is actuated 2 s after actuation of the pre limit switch travel in the CLOSE direction continues up to the limit position...

Page 30: ...fore the running time has elapsed This operating mode can be used for hydraulic drives with mechanical limit stop for example Internal limit switch M A1 01 If the door travels to the internal limit sw...

Page 31: ...ime the input is actuated The second time the input is actuated the door starts moving in the actuated direction If actuation occurs when the door is running in the opposite direction and a panic func...

Page 32: ...loses The potential free contact of a timer allows the automatic reclosing opera tion to be controlled Standby power standby operation In order to save the standby power the control unit enters standb...

Page 33: ...C7 00 menu items can be modified as delivered condition M C7 01 no changes possible Disable enable parametrisation Continuously actuate EMERGENCY STOP Select menu M C7 and access menu item with Ta M...

Page 34: ...e control Caution If a radio control system is used the person operating the door must have full view of the door and its surroundings while the door is moving and ensure that he she is clear of all h...

Page 35: ...red function with Ta or Ta 3 Now press and hold the operating or programming button on the transmitter until the selected function F1 F2 is permanently displayed no longer flashes The transmitter has...

Page 36: ...ontrol and drive cables Routing in cable ducts alongside other cables will reduce the range and possibly lead to malfunc tions If the dead man function has been set via M b3 M b4 the corresponding dir...

Page 37: ...voltage wait 10 s switch operating voltage back on If the error message persists the motor current detection is faulty The control unit must be replaced 03 N relay cutoff Switch off operating voltage...

Page 38: ...g M A2 when the closing edge safety device is connected b Check connection of the closing edge safety device especially earth connection at terminal Kl 14 c If a and b are correct an error pos sibly e...

Page 39: ...Switch off operating voltage wait 10 s switch operating voltage back on If the error message persists a Check setting M A4 external LS test with regard to connected light barrier b Check connection of...

Page 40: ...ric safety edge Travel command OPEN Pre limit switch Travel command pulse Travel command CLOSE Light barrier 3 4 5 6 7 8 N 9 230V AC Licht 230V PE N L M NOT 12V 10 11 12 13 14 15 16 17 18 19 20 21 22...

Page 41: ...Electric safety edge and light barrier connecting diagram C 8K2 C NO NC Light barrier transmitter Light barrier receiver Electric safety edge 41...

Page 42: ...for installation indoors Supply voltage 230 V 50 Hz connection type Y Input power 6 V A Fuse 5 A slow blow Si3 5 x 20 mm Drive switching capacity 1 drive 230 V 50 Hz maximum 500 V A Light switching c...

Page 43: ...Declaration of conformity 43...

Page 44: ......

Reviews: