12 V DC output (stabilised)
[Kl.18]
0V / Earth
[Kl.20]
0V / Earth
Connection for external consumer, e.g., OSE, light barrier, etc.
Attention! The maximum current specified in the "Technical data" must not be
exceeded! Non-compliance can lead to malfunctions, failure, destruction and
property damage.
Safety input
[Kl.11]
+12 V (continuous)
[Kl.12]
+12 V (with testing)
[Kl.13]
SE1 signal input
[Kl.14]
Common
[Kl.15]
SE2 signal input
[Kl.18] or [Kl.20]
0V / Earth
•
Safety input category 2 / Performance Level C to EN ISO 13849-1/2008
•
The
type of the input
is set in [M.A2] for SE1 and [M.A4] for SE2.
∙
Input for safety contact strips (1k2
or
8k2
or
OSE) for closing edge safety device
∙
Input for light barriers (LS)
•
The
function
of the input is set in [M.A3] for SE1 and [M.A5] for SE2.
∙
Setting the function of the safety input for travel in the OPEN direction and travel
in the CLOSE direction
∙
Stop: Drive remains at standstill
∙
Reverse travel: When approaching an obstruction, the door is actuated in the
opposite direction for the set reverse travel time [M.b1].
∙
Reopening/reclosing: If a safety device is actuated when the drive is in operation
(e. g., detects obstruction in the active direction of travel) the door then travels
in the opposite direction up to the limit position.
•
When the SE input is actuated
the drive can only be started if the SE setting is
not effective in the corresponding direction of travel. If effective, travel will not be
possible in the direction of travel.
•
When the drive is in operation
a command at the SE input effects the following:
stop, reverse travel, reopening, reclosing or no effect, depending on the direction
of travel and setting.