1
1
2
3
4
5
4
6
5 mm
MOUNTING
Remove the mounting base.
Remove the cover.
Do not hesitate to pull, the cover is very resistant.
Fix the mounting base using the 3 screws.
Make sure the sensor does not collide with any objects
during the door movement.
If necessary, drill a hole for the master-slave cable in
the striped zone.
Pull the master-slave cable through the hole and
position it as shown.
Position the sensor in front of the base and pull
the connector through. Then fit the sensor onto
the base by entering the cross-shaped parts into
the cross-shaped holes.
The base has to be attached firmly.
For optimum safety, install 1 module on each door wing side and interconnect them via the master-slave cable.