TROUBLESHOOTING

The ORANGE LED 
flashes 1 x 
every 3 seconds.

Bad teach-in

The ORANGE LED is 
on permanently.

The ORANGE LED 
flashes quickly.

The RED or GREEN 
LED is ON sporadicly 
or permanently. 

Launch a new teach-in (closed door).

Send the sensor back for a technical check-up.

Corfirm the DIP-switch setting: long push on the 
push button.

Cut and restore power supply.
If orange LED flashes again, replace sensor.

The ORANGE LED 
flashes 2 x 
every 3 seconds.

The ORANGE LED 
flashes 3 x 
every 3 seconds.

The ORANGE LED 
flashes 4 x 
every 3 seconds.

The ORANGE LED 
flashes 5 x 
every 3 seconds.

Check power supply (tension, capacity).
Reduce the cable length or change cable.

Check wiring between master and slave modules.
Check wiring between interface card and laser head.

Change background setting if necessary (DIP 3).

Power supply is out of limit.

The sensor signals an 
internal fault.

Communication error

No laser beam is coming 
back to the sensor.

The sensor encounters a 
memory problem.

DIP-switch setting 
awaiting confirmation.

Teach-in error

Check whether all teach-in requirements are fulfilled.

Launch a new teach-in (closed door).

An object close to the 
sensor is masking part of 
the detection area.

Make sure the window is not scratched.
Remove all masking objects.
Change anti-masking setting if necessary.
Clean window with damp cloth.

The ORANGE LED 
flashes 6 x 
every 3 seconds.

Faulty measurements of 
door position.

Normally the door will try to close.
Activate and deactivate service mode and launch a 
door opening cycle.
Cut power supply and restore it once the door is fully 
closed.

Unwanted detection

Deactivate pinch zone (DIP 4 off) to check which 
detection zone causes the detections.
Make sure the flexible cable does not cause detections.
Check changes in the environment.

The sensor does not 
react at power-on.

The service mode is 
activated.

Press the push button during at least 2 seconds to 
exit the service mode.

Internal temperature is too 
high.

Protect the sensor from any heat source (sun, hot air...)

It is not possible to 
adjust a setting by 
remote control.

Wrong DIP-switch position.

Adjust the required DIP-switches to ON.

The remote control 

does not react.

Enter the right password. If you forgot the code, cut 
and restore the power supply to access the sensor 
without entering a password during 1 minute.

The sensor is protected by 

a password.

Inverted power supply

Check wiring (green +, brown -).

In case of unwanted reactions of the door, verify whether the problem is caused by the sensor or the door controller. 

To do so, activate the service mode (no safety) and launch a door cycle. 

If the door cycle is completed successfully, check the sensor. If not, verify the door controller or wiring.

The sensor does not 
react.

Check tension between red and blue wires.

Test error

Summary of Contents for LZR FLATSCAN SW

Page 1: ...E N A B L E S A C C O R D A N C E W I T H E R L A U B T Z E R T I F I Z I E R U N G N A C H DIN 18650 E N A B L E S A C C O R D A N C E W I T H DRAFT EN SAFETY SENSOR FOR AUTOMATIC SWING DOORS User s Guide for product version 0200 and higher See product label for serial number ...

Page 2: ...t installations or inappropriate adjustments of the sensor Only trained and qualified personnel may install and setup the sensor The warranty is invalid if unauthorized repairs are made or attempted by unauthorized personnel Always test the good functioning of the installation before leaving the premises The door control unit and the door cover profile must be correctly earthed MAINTENANCE SAFETY ...

Page 3: ...slave connector 5 main connector 6 hole for master slave cable 7 clamp with flexible kit 8 plug without flexible kit 9 flexible kit 10 positioning aids 11 DIP switch 12 laser head 13 laser window 14 angle adjustment screw 15 cover 16 master slave cable LED flashes quickly Calculation in progress Exit the zone and wait For optimum safety install 1 module on each door wing side and interconnect them...

Page 4: ...ecessary drill a hole for the master slave cable in the striped zone Pull the master slave cable through the hole and position it as shown Position the sensor in front of the base and pull the connector through Then fit the sensor onto the base by entering the cross shaped parts into the cross shaped holes The base has to be attached firmly For optimum safety install 1 module on each door wing sid...

Page 5: ...the MASTER module plug both connectors Position the cable wires as shown in order to prevent water infiltration and crushing of the wires MASTER connected to the door controller 3 Position the flexible tube clip on the clamp and fasten the screws 4 Fasten the flexible tube on the other end as shown Make sure the flexible tube is not detected MASTER connected to the door controller Lock the sensor ...

Page 6: ...on R1 RED R2 GREEN RELAY 2 Adjust DIP 1 according to the door side on which the module is mounted Adjust the other DIP settings only if needed Switch to CRITICAL when external disturbances are likely to cause unwanted detections min obj size immunity and uncovered zone are increased Switch to OFF when there is no background glass floor footbridge Switch to OFF when the hinge area does not need to ...

Page 7: ...the MASTER and the SLAVE A teach in on the SLAVE only configures the SLAVE Launch a teach in on the MASTER module by push button or remote control 1 Wait until the LED flashes green then indicate the edge of the door wing with your hand 2 Wait until the LED flashes green again and activate an opening and closing cycle of the door 3 Wait until the LED goes out The service mode deactivates the safet...

Page 8: ...ts spots STANDARD EXTENDED sec off off The standard holdtime maintains the output active for 0 3 1 or 2 seconds When the extended holdtime is chosen the sensor extends the holdtime during 15 30 or 60 seconds in case of short detections during the opening of the door This parameter defines the minimum object size to be detected Its size is represented by the number of spots it covers in the safety ...

Page 9: ...ry reset of all values exept field dimensions and output configurations See page 7 FACTORY VALUE Antimasking protective function which ignores an unwanted object nearby the laser window masking the vision field Background reference point in the detection field of the sensor If no background is present switch to off Increase to filter out external disturbances The reaction time increases significan...

Page 10: ...he red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits If you do not know the access code cut and restore the power supply During 1 minute you can access the sensor without introducing any access code field width 2 35 m To end an adjustment session always lock the sensor Enter the existing code x number of flashes value of the parameter full reset partial re...

Page 11: ...g objects Change anti masking setting if necessary Clean window with damp cloth The ORANGE LED flashes 6 x every 3 seconds Faulty measurements of door position Normally the door will try to close Activate and deactivate service mode and launch a door opening cycle Cut power supply and restore it once the door is fully closed Unwanted detection Deactivate pinch zone DIP 4 off to check which detecti...

Page 12: ...solution Door wing safety 1 3 Pinch zone safety 0 2 Typ min object size Door wing safety Pinch zone safety 10 cm 4m in proportion to object distance 2 cm 4m in proportion to object distance Testbody 700 mm 300 mm 200 mm testbody A according to EN 16005 DIN 18650 Emission characteristics IR LASER Wavelength 905 nm max output pulse power 25 W Class 1 Supply voltage 12 24 V DC 15 Power consumption 2 ...

Reviews: