background image

BCD-RGD-804P-MT

4

www.bcdvideo.com

1.1.4  Check network whether connect between computer and switch

Use the ping command of Operating System, enter switch’s IP address, if reply normally, then network connectivity;  
otherwise, check the network connection.

1.1.5  Login switch management interface

Running the browser, enter the switch default IP address (192.168.0.240) in address column, click Enter. Login dialog box, 
as shown below, enter your user name and password (the default user name: admin, password: admin), click the OK  
button or directly enter into the system configuration page. After a successful login interface as follows:

Summary of Contents for BCD-RGD-804P-MT

Page 1: ...1 1 847 205 1922 info bcdvideo com www bcdvideo com BCD214 RGD 804P MT USER GUIDE...

Page 2: ...ment interface 4 1 2 Web management interface 5 1 2 1 Basic information 5 1 2 2 Configuration 7 5 2 3 Monitor Status Display 60 5 2 4 Diagnostics 89 5 2 5 Maintenance 91 2 Command Line Management 93 2...

Page 3: ...assword admin 1 1 2 Computer basic configuration requirement Ethernet card installed you can access the Internet through a network port we recommend using a Computer or better minimum display resoluti...

Page 4: ...y otherwise check the network connection 1 1 5 Login switch management interface Running the browser enter the switch default IP address 192 168 0 240 in address column click Enter Login dialog box as...

Page 5: ...elow Port State Overview This area displays the current status of the device connection port When the indicator is green indicates that the corresponding port is connected the indicator is gray indica...

Page 6: ...ption the system will expand to show the relevant status interface user related functions can be provided in the interface Diagnostics Click on the navigation column Diagnostics option the system will...

Page 7: ...e Interface items introduction Interface items Configuration Introduction Factory configuration System Contact 0 255 characters Equipment maintenance personal contact information No System Name 0 255...

Page 8: ...different hosts in VLAN access to the switch Interface items Configuration Introduction Factory setting Delete Select not selected Select this option to delete an existing IP interface not selected V...

Page 9: ...not selected Network IP address The destination IP network or host address of this route Valid format is dotted decimal notation or a valid IPv6 notation A default route can use the value 0 0 0 0 or I...

Page 10: ...rver IP address No 5 2 2 2 Ports Enter the Ports navigation column you can view the connection status of each port including link connection speed flow control and maximum frame size and other informa...

Page 11: ...802 3u 10Mbps HDX In accordance with the rate selection full half duplex com munication rate and to determine its mode of operation 10Mbps FDX 100Mbps HDX 100Mbps FDX 1Gbps FDX Flow Control Current Rx...

Page 12: ...is used to add users change user account password important to remember the new password the password is lost login prevent equipment failure Interface items Introduction Add New User Add new user Use...

Page 13: ...enable user name and password to log in the system s local user database When you select the authentication mode is radius enable remote server for authentication Set relevant parameters click Save to...

Page 14: ...Enable Off On HTTPS access switch Disable Automatic Redirect Disable Enable Off On automatic redirection between HTTP HTTPS Disable C HTTPS Configuration Enter Switch HTTPS configuration navigation co...

Page 15: ...oduction Factory setting Mode Disable Enable off one access control management Disable VLAN ID 1 4095 IP segment belongs VLAN 1 Start IP Address IP Address Access the start IP address 0 0 0 0 End IP A...

Page 16: ...rivate Engine ID 16Decimal Indicates the SNMPv3 engine ID The string must contain an even number in hexadecimal format with number of digits between 10 and 64 but all zeros and all F s are not allowed...

Page 17: ...ry setting Mode Disable Enable Indicates the trap mode operation Possible modes are Enabled Enable SNMP trap mode operation Disabled Disable SNMP trap mode operation Disable Interface items introducti...

Page 18: ...message via this port the port range is 1 65535 162 Trap Inform Mode Disable Enable Indicates the SNMP trap inform mode operation Disable Trap Inform Tim eout 0 2147 second Indicates the SNMP trap inf...

Page 19: ...thentication no privacy NoAuth NoPriv Auth NoPriv authentication no Privacy Auth Priv authentication Privacy Authentication Protocol MD5 SHA Select the authentication encryption algorithm MD5 Authenti...

Page 20: ...or the user to use Snmp access Interface items Introduction F SNMP View Configuration Enter SNMP configuration Views navigation column Configure SNMPv3 view table on this page The main configuration i...

Page 21: ...exclude OID subtree node Included OID Subtree Use separated string of numbers OID Mark 1 Default_rw_group Interface items Configuration Introduction Factory setting Group Name 0 255 byte User group n...

Page 22: ...02 1X standard defines port based operation but non standard variants overcome security limitations as shall be explored below MAC based authentication allows for authen tication of more than one user...

Page 23: ...ame Default_ro_group Period 1 3600 second Recertification interval 3600 EAPOL Timeout 1 65535 second Identity EAPOL defined time frame resend request and this time on the MAC based authentication is i...

Page 24: ...without authentication Force Authorized Note If set to a non Force Autho rized port you can not open the port Spanning tree and Aggregation functions Force Unauthorized In this mode when a client is c...

Page 25: ...can receive the frames matching ACE parameter Also define eight per port policy number each policy is defined different content you can configure the following parameters Series Action Permit Deny to...

Page 26: ...mirrored or not mir rored Disabled Frames received on the port are stored in the System Log or not logged Disabled Logging Disabled Enabled Frames received on the port are stored in the System Log or...

Page 27: ...control List Enter ACL configuration Access Control List navigation column Check system access control lists Click to add ACE term of list Interface items Configuration Introduction Factory setting R...

Page 28: ...P protocol IPV4 other ACE matching the otherIPV4 frames except ICMP UDP TCP protocol IPV6 ACE match all IPV6 frame Action Permit Forwarding and Learning with ACE matching frame Permit Deny Discard the...

Page 29: ...US server and switch No NAS IP Address IP address NAS logical IP address No NAS Identifier 0 255 byte NAS authentication string No 5 2 2 6 AAA authentication authorization accounting configuration Ent...

Page 30: ...n Introduction Factory setting Delete Hostname IP address RADIUS server IP address 1812 Auth Port Port No RADIUS server UDP port used for authentication 1813 Acct Port Port No RADIUS server UDP port u...

Page 31: ...combination computing Support 5 groups aggregation each supports up to 10 ports as shown 1 2 opening set of aggregation 3 4 opening set of aggregation and so on Aggregation group member ports Please...

Page 32: ...ct Interface items Configuration Introduction Factory setting Group ID Normal 1 5 Indicates the group ID for the settings contained in the same row Group ID Normal indicates there is no aggregation On...

Page 33: ...hering information according to the parameters and status auto matic matching link aggregation together send and receive data After forming aggregation switching equipment mainte nance aggregation lin...

Page 34: ...t Auto Role Active Passive The Role shows the LACP activity status The Active will transmit LACP packets each second while Passive will wait for a LACP packet from a partner speak if spoken to Not sel...

Page 35: ...lect Controls whether loop protection is enabled on this switch port Select Action Shutdown Port loop is detected on a port Shutdown the Port Shutdown Port Shutdown Port and Log Loop detected shutdown...

Page 36: ...ation to 20 Transmit Hold Count 1 10 The number of BPDU s a bridge port can send per second When exceeded transmission of the next BPDU will be delayed Valid values are in the range 1 to 10 BPDU s per...

Page 37: ...users can manually specify among 1 200000000 the smaller the value the more priority path Port priority use in the spanning tree calculation process for 0 16 32 48 224 240 the default is 128 Edge port...

Page 38: ...message to other ports BPDU Guard Select not Select When Selected the port does not receive a valid BPDU not Select Point to Point Auto Device Automatic detection link is connected to this port is poi...

Page 39: ...IGMP Snooping is en abled the flood control takes effect when IGMP Snooping feature is disabled can not be controlled flooding tick IGMP SSM Range IGMP SSM range Leave Proxy Enabled tick not tick Leav...

Page 40: ...k displays list Interface items Configuration Introduction Factory setting Delete Delete the corresponding IGMP Snooping VLAN list VLAN ID 1 4095 Setting IGMP Snooping VLAN range 1 4095 No Snooping En...

Page 41: ...n interface identifications and other information organized into different TLV Type Length Value type length value and Package link layer discovery pro tocol data unit link Layer Discovery Protocol Da...

Page 42: ...ly transmit LLDP frames Port Descr Tick Not tick When ticked the port description information transmit contained TLV in LLDP frame and did not tick the TLV infor mation is not included in LLDP frame t...

Page 43: ...BCD RGD 804P MT 43 5 2 2 12 POE Enter POE navigation column Set the value of the PoE...

Page 44: ...Power Supply W 2000 2000 Interface items Introduction Factory setting PoE Mode Disabled PoE PoE Disabled Priority Low High Low Maximum Power W 15 4 Power Over Ethernet Configuration Interface items in...

Page 45: ...MAC address table dynamically updated timeout 300 Interface items Introduction Factory setting Auto Select Open port MAC address auto learning function Selected Disable Select Cancel port MAC address...

Page 46: ...AC address table added to the corresponding port in MAC address table All not selected Static MAC address configuration Interface items introduction Click on Add a New Static Entry to add a new static...

Page 47: ...ress belong to VLAN ID 1 MAC Address MAC address MAC address add to MAC address table 00 00 00 00 00 00 Port Members Recheck 1 n port After selecting the port MAC Address in the MAC address table adde...

Page 48: ...added to back inside of Allowed Access vlans Ingress Filtering refers to the port receives the packets that do not match choose to drop or forwarded the default port input filtering function is disabl...

Page 49: ...service port S Custom Port Port as service custom port Ingress Filtering Refers to the port receives the packets that do not match choose to drop or forwarded the default port input filtering function...

Page 50: ...on to compete the private VLAN membership configuration Select the Delete option in front of the corresponding VLAN ID click Save button to delete the private VLAN members Interface items Configuratio...

Page 51: ...can achieve isolation between Layer 2 data within the isolation group port Port isolation provides users with a more secure and flexible networking schemes Interface items Configuration Introduction...

Page 52: ...ame discard class 0 no dropped frames 1 drop frames during congestion 0 PCP 0 7 802 1Q VLAN priority tag frames if the port is VLAN aware and the frame has a VLAN tag this value will be inserted into...

Page 53: ...ity tag frames if the port is VLAN aware and the frame has a VLAN tag this value will be inserted into the VLAN priority bits field VLAN tag Otherwise it will insert the default VLAN priority 0 Unit K...

Page 54: ...items Configuration Introduction Factory setting Port 1 n Switch Port ID need to configure 1 n Mode Strict Priority Weighted Port schedule mode Strict Priority Weight Qn show line 1 5 weighted 500 In...

Page 55: ...BCD RGD 804P MT 55 Scheduler Mode configure to Weighted interface show as below...

Page 56: ...not select After select queue can use excess bandwidth not select Queue Scheduler Weight 1 100 Set the queue percentage weight 17 Queue Scheduler Percent show the queue percentage weight 17 Port Shape...

Page 57: ...ected Strict Priority Shapers Qn shows each queue configuration Shapers Port shows each port configuration Interface items introduction E Qos control list Enter QoS Control List navigation column conf...

Page 58: ...range to be recognized of the input data stream Any All VLAN Specific a specific VLAN Range a VLAN range Any Key Parameters PCP Any 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 3 4 7 Select the recognized priori...

Page 59: ...designated port as the destination port the port is mapped source port mirroring port mirroring connected to the network analytical instruments you can clear analysis mirroring port packets without di...

Page 60: ...sabled Port 1 n Switch physical port number 1 n Mode Disabled Close Port Mirroring Disabled Rx Only Only received frames are mirrored Tx Only Only transmit frames are mirrored Enabled Transmit and rec...

Page 61: ...figure switch location MAC Address Switch MAC address Chip ID Switch chip ID System Date System date System Uptime System uptime Software Version Software version Software Date Software date Interface...

Page 62: ...l ALL Info Warning Error ID Log index ID Level Log level Time Log Time date Message Log message Interface items introduction Page operating button Refresh Clear view the first log view the Previous lo...

Page 63: ...ssage Log message Interface items Introduction Local Port Switch physical port number Temperature Temperature Port status Display the port link status Interface items introduction Interface items intr...

Page 64: ...ou can see the number of packets trans mitted and received for each port the number of bytes transmitted and received error packets When have too many error message it indicates the working status of...

Page 65: ...tes Received Bytes Transmitted Bytes Transmitted Errors Received Errors Received Errors Transmitted Errors Transmitted Drops Received Drops Received Drops Transmitted Drops Transmitted Fitered Receive...

Page 66: ...you can query detailed oper ation of each port including receiving the transmitted packets broadcast packets error packets etc to facilitate network management for network maintenance personnel Drop d...

Page 67: ...number of Rx 128 255 Bytes Rx 256 511 Bytes Frame number of Rx 256 511 Bytes Rx 512 1023 Bytes Frame number of Rx 512 1023 Bytes Rx 1024 1526 Bytes Frame number of Rx 1024 1526 Bytes Rx 1527 Bytes Fra...

Page 68: ...me Rx Fragments The number of received frame with invalid CRC frame length less than 64 Rx Jabber The number of received frame with invalid CRC frame length over max frame Rx Filtered The number of fi...

Page 69: ...onfiguration to match the input frame Action DSCP To add DSCP value for parameter configuration to match the input frame Conflict Status indicator whether conflict with other QoS control items Interfa...

Page 70: ...ter Port Security Switch navigation column display port switch security on page User can select Auto refresh but ton to refresh data in real time Can also be manually Click Refresh button to see the n...

Page 71: ...Click Refresh button to see the new data Interface items Description User Module Name The module name can request a port security services Abbr User name Single letter abbreviations Port Switch physic...

Page 72: ...mode MAC Based Auth Using MAC based authentication mode Port State Port state Globally Disabled NAS all Disabled Link Down NAS all Enabled but port cant link Authorized Port operates in Force Authori...

Page 73: ...Deny discard the frame matching ACE Filter filter the frame matching ACE Rate Limiter Disabled 0 16 rate limit ID use on port Port Redirect Disabled Port ID Whether Port Frame is re directed if redire...

Page 74: ...y the authentication state of RADIUS server on page User can select Auto refresh button to refresh data in real time Can also be manually Click Refresh button to see the new data Interface items Intro...

Page 75: ...the server Interface items Description Access Accepts The number of access requests packets sent to the server Access Retransmissions The number of Access Retransmissions packets sent to the server P...

Page 76: ...n B LACP port status Enter LACP Port Status navigation column This page displays LACP physical port information User can select Auto refresh button to refresh data in real time Can also be manually Cl...

Page 77: ...ace items Description Port Switch physical port ID LACP LACP status Yes LACP on and connected port No LACP off and port disconnected Key Communication key Aggr ID Aggregation Examples ID Partner Syste...

Page 78: ...navigation column can view bridge ID Root bridge ID port path cost and oth er information User can select Auto refresh button to refresh data in real time Can also be manually Click Refresh button to...

Page 79: ...Bridge instance ID Root ID Current root ID Root Cost Root path cost Root Port Designated port for the root bridge Regional Root Be selected to regional root bridge ID Internal Root Cost Internal root...

Page 80: ...Edge Edge port instructions Yes port edge port No ports are non edge port Point to Point The current state of the STP is point to point Uptime The last uptime of bridge port B Spanning Tree Port stat...

Page 81: ...er of STP BPDU Transmitted TCN Port transmitted the number of TCN BPDU Received MSTP Port received the number of MSTP BPDU Received RSTP Port received the number of RSTP BPDU Received STP Port receive...

Page 82: ...tems introduction Interface items Description VLAN ID VLAN ID Querier Version Working Query Version Host Version Working Host Version Querier Status Querier Status Queries Transmitted The number of tr...

Page 83: ...lect Auto refresh button to refresh data in real time Can also be manually Click Refresh button to see the new data Router port Interface items instruction Interface items instruction Interface items...

Page 84: ...esh button to refresh data in real time Can also be manually Click Refresh button to see the new data Interface items introduction Interface items Description Local Port Receiving the port number of L...

Page 85: ...al Counter Interface items instruction Interface items Description Neighbour entries were last changed Receiving the port number of LLDP frame Total Neighbours Entries Added Neighbor s LLDP frame incl...

Page 86: ...f after receiving the discard LLDP frames TLVs Discarded The number of discarded TLV information sheet TLVs Unrecognized The number of unrecognized TLV information Org Discarded The number of Organize...

Page 87: ...lated MAC items Port Members Corresponding port of Related MAC items Interface items Description VLAN ID VLAN ID of corresponding port Port Members VLAN ID including port 5 2 3 12 VLANs status A VLAN...

Page 88: ...port The number of wrong LLDP frames received S Port port as service port The number of after receiving the discard LLDP frames S Custom Port as user service port The number of discarded TLV informat...

Page 89: ...packet sending interval range 0 30 default is 1 Interface items instruction 5 2 4 Diagnostics Diagnostics navigation column including ping and VeriPHY function 5 2 4 1 Ping Enter Ping navigation colu...

Page 90: ...port ID Pair A B C D Cable Differential pairs connected state OK normal The number of LLDP frames received Open Open circuit The number of wrong LLDP frames received Short Short circuit The number of...

Page 91: ...aults Enter Factory Defaults Navigation Column When need to revert to the original system defaults can choose to restore the factory configuration functions The default configuration for all configura...

Page 92: ...evice all changes need to be saved here otherwise changes will not take effect Enter Configuration Save startup config Navigation Column Save the current configuration if not save restart device will...

Page 93: ...gation Column can upload the previous configure file to switch by upload function to achieve configuration updates Beside WEB management Amber Series also support command line management 2 1 Configure...

Page 94: ...the serial management port of Switch For example Hyper Termi nal SecureCRT Putty and so on SecureCRT soft ware will be used in the descrip tion below 2 Select the COM port to use and click OK 3 Set t...

Page 95: ...e in serial terminal interface 2 2 Login equipment and basic command Query Note The command can be entered only the first four characters the other can be used as usual omitted 2 2 1 System Informatio...

Page 96: ...to enter a user name and password enter the appropriate commands into the relevant settings and queries At the command prompt type Or help to get help The following equipment for the VLAN1 IP 2 2 5 Us...

Page 97: ...1000 Base X 100 Base FX Power Supply Power input PWR1 45 57VDC PWR1 45 57VDC Power reverse protection Present at terminal block Power Consumption 10W No POE POE POE IEEE 802 3af 802 3at POE POE outpu...

Reviews: