8. THE DISPLAY
The DigiQ’s three digit LED display has three status indicators.
BLOWER STATUS INDICATOR
The Blower Status Indicator and Blower Display Warble will help determine how the fire is being controlled. When there
is sufficient fuel in the pit, the blower will gently puff the fire, feeding it little bursts of oxygen. When the blower is
energized, the display will blink about once per second (blower warble) and the blower status indicator will turn on. When
the pit starts to run out of fuel, the blower will run almost all of the time.
DETERMINING THE OUTPUT PERCENTAGE FROM THE BLOWER WARBLE
The Blower Warble is designed so that the output percentage of the blower can be determined by counting how many
display blinks (warbles) occur in a given cycle as per the table below:
TIP: If the output percentage is around 80-100% for a long time, the pit may be running out of charcoal. If the output
percentage is around 10% for a long time and the temperature is oscillating, close the blower damper adjustment slightly
for better control.
8.2. FOOD DONE MESSAGE
When the food temperature reaches or exceeds the food setpoint, the display will scroll
and the beeper will
sound.
8.3. OVER/UNDER RANGE TEMPERATURE
If the temperature goes below 32 or above 485 degrees F on the food or pit probe, the display will show