10. SETUP MENU
Press the UP & DOWN keys simultaneously to enter the setup menu. The screens below are shown in the order they
appear as the UP + DOWN keys are pressed again. When the F/C select is reached and the UP + DOWN keys are pressed
again, the setup menu loops, so the pit temperature will be displayed again.
ALARM DEVIATION SETPOINT
If the temperature of the pit deviates above the setpoint by the alarm deviation setpoint, the alarm will sound and the
display will blink
. If the temperature of the pit deviates below the setpoint by the alarm deviation setpoint, the
alarm will sound and the display will blink
.
The alarm will not sound when the control is first powered up and the pit is cold. The alarm is only allowed once the
temperature gets close to the pit temperature setpoint. The alarm deviation is settable from 20 to 125 degrees F and the
factory default is 50 degree F.
If the ramp feature is turned on and the pit is actively ramping, the only time that the low alarm will become active is if
the pit temperature drops 20 degrees below the food setpoint temperature.