RPC SERIES OWNER’S MANUAL
RPC SERIES QUICK START (RPC-3, RPC-3A, AND RPC-5)
________________________________________________________________________________
9
RPC-3 Telnet Host
Revision F 3.03, (C) 1998
Bay Technical Associates
Unit ID: RPC3
RPC-3 Menu:
1) . . . Outlet Control
2) . . . Manage Users
3) . . . Configuration
4) . . . Unit Status
5) . . . Reset Unit
6) . . . Logout
Enter Selection:
If the main menu fails to appear, ensure the
correct cables and adapters are being used
and that they are connected properly. Also,
verify the serial communication
parameters are correctly configured.
Outlet Control
From the RPC> prompt, enter one of the
following commands: ON n, OFF n,
REBOOT where “n” is the outlet number
you want to command. Entering an outlet
number of “0” sends the command to all
outlets. Type “MENU” to return to the
main menu. . Reboot only works on outlets
which are in the “ON” condition.
Manage Users
New users (a maximum of 4 for the RPC-5
or 8 for the RPC-3/3A) may be added or
deleted using this menu. Any time there is
more than 1 user besides the admin, a
“Delete user” function will appear. Any time
the maximum number of users is reached,
the “Add user” function will disappear.
Deletion of the admin user is prohibited.
Summary of Contents for RPC-2
Page 7: ... vii ...
Page 79: ...RPC SERIES OWNER S MANUAL APPENDIX E 72 APPENDIX E DRAWINGS RPC 2 ...
Page 80: ...RPC SERIES OWNER S MANUAL APPENDIX E 73 APPENDIX E DRAWINGS RPC 2A ...
Page 81: ...RPC SERIES OWNER S MANUAL APPENDIX E 74 APPENDIX E DRAWINGS RPC 2 MD01 ...
Page 82: ...RPC SERIES OWNER S MANUAL APPENDIX E 75 APPENDIX E DRAWINGS RPC 2 RDR ...
Page 83: ...RPC SERIES OWNER S MANUAL APPENDIX E 76 APPENDIX E DRAWINGS RPC 3 ...
Page 84: ...RPC SERIES OWNER S MANUAL APPENDIX E 77 APPENDIX E DRAWINGS RPC 3A ...
Page 85: ...RPC SERIES OWNER S MANUAL APPENDIX E 78 APPENDIX E DRAWINGS RPC3 3A 5 ETHERNET BOARD ...
Page 86: ...RPC SERIES OWNER S MANUAL APPENDIX E 79 APPENDIX E DRAWINGS RPC 5 ...