IMPORTANT NOTICE
The system operator must ensure compliance with the relevant accident prevention conditions, with all legal
regulations, and with the generally recognised technical safety principles!
4
Default access codes
HAZARD!
Unauthorised access possible from using known access codes
Access codes facilitate access to critical areas on the system. Unauthorised access can lead to dangerous configurations.
Potential consequence:
Severe or possibly fatal injury, serious damage to property.
Configure individualised access codes. Under no circumstances should the preconfigured standard access codes be used.
Keep access codes strictly confidential.
The following table indicates the standard default access codes.
Menu
Default access code
(should be changed in the menu Controller Settings > Code Numbers!)
Main Menu (Customer) 1234
Main Menu (Service)
5678
5
Installation of Pool Relax
5.1
General Information
Perform all installation work carefully and comply with the applicable safety regulations. During installation, disconnect the
measurement, control and dosing device and all other electrical loads such as the electrical heating or the circulating pump from the
mains.
In addition, comply with the applicable regulations regarding the installation of electrical devices.
General notes on installation:
Ensure that the hoses are laid without kinking and that chafing cannot occur.
Avoid laying the hoses over sharp edges.
Carefully connect all hoses and check that the connections are firmly attached.
Avoid unnecessarily long hose lengths.
Do not guide the hoses directly over warm pipes or systems.
Check that the float in the measurement chamber can float freely.
Adjust the water flow through the cell so that the float just barely lies against the upper end in its guide bore.
If you are using a Flockmatic
®
pump for dosing Quickflock Automatic Plus, please connect it to a connection controlled by the
circulating pump (circulation OFF – flocculation OFF; circulation ON – flocculation ON)
5.2
Selecting the Installation Location
To mount Pool Relax, select a dry, frost-protected, sheltered and level location on a vertical wall. Ensure that the area is readily
accessible and well ventilated. There should be no energized electrical cables, contactors, electric motors, etc. in its vicinity. The
installation location should be as close as possible to where the measuring water is extracted and returned.
The supply voltage for the controller and the vacuum pumps should not exceed 240V/50 Hz. The allowable operating temperature
range is from 0 to 50
°
C, and the allowable humidity level equals 0-90 %.