14
46
14
Event log
14.1
Overview
The event log records all important events concerning Pool Relax. It is an important aid in monitoring the correct operation of the
swimming pool system and analysing possible problems.
The event log can be opened from the main menu. It records up to 100 events with date and time.
The following events are recorded:
Switching on and off of Pool Relax
Alarm conditions (beginning and end)
Calibration
Parameter changes
O2 dosing
Default resets
Since all entries are displayed by Pool Relax in easily comprehensible text, a detailed depiction of the individual events will not content
be provided here.
The following example illustrates the contents of the event log:
1 06.06.2017
08:44
Main dosing O2 ended (2.4/2.4l)
2 06.06.2017
08:30
Main dosing O2 continued (1.0/2.4l)
3 06.06.2017
08:30
(Level alarm O2) end
4 06.06.2017
08:10
Main dosing O2blocked (level)
5 06.06.2017
00:10
Level alarm O2
6 06.06.2017
00:00
Main dosing O2 started (2.4l)
This sequence in the event log has the following background:
At midnight, Pool Relax starts an O2 main dosing with a dose amount of 2.4 litres. After 10 minutes, the Bayrosoft
®
canister is empty.
This causes a level alarm that blocks the O2 main dosing. The next morning at 8:00 a.m., the empty Bayrosoft
®
canister is replaced.
The level alarm ends and the O2 main dosing is continued, where 1.0 litre of Bayrosoft
®
had already been dosed prior to the level
alarm. Thus, only an additional 1.4 litres must be dosed. At 8:44 a.m., the O2 main dosing is ended as planned after the full amount of
2.4 litres was dosed.
Summary of Contents for Pool Relax Bromine