Mounting Pool Relax on the Wall
1
2
3
1.
The base plate with the mounted measurement cell can be used as a template by holding it up against the mounting
location and marking the drill holes on the wall.
2.
After the base plate is securely mounted on the wall, the controller housing is attached to the tongue and groove joint
provided for this purpose.
3.
The housing is attached using a slotted screw, (see picture).
Connect the supplied pH pressure line on one side with the pressure side (right connector) of the left-hand vacuum pump. Connect
the other side with the upper
injection piece of the measurement cell. Ensure that the connection is tight and securely fastened.
Connect the supplied pressure line for Chloriliquide or Bayrosoft
®
on one side with the pressure side (right hand hose connector) of
the right-hand vacuum pump. Connect the other side with the upper injection piece of the measurement cell. Ensure that the
connection is tight and securely fastened.
Connect the flow switch and the temperature sensor (Pool Relax Oxygen only). Ensure that the connectors are inserted in the
sockets provided for this purpose (see the "Stickers on Controller Housing" and "Connections on Controller Housing" chapters).