9.2 

The pH FUN does not display the correct pH value 

 

Cause

 

Remedy

 

The displayed pH value 
on the pH FUN deviates 
greatly from the check 
measurement using 
colour strips or Phenol 
Red tablets.

 

  The check measurement may 

possibly be incorrect. 
 
 

  A new pH7 calibration of the pH 

FUN may possibly be necessary 
or even a replacement of the pH 
electrode under certain 
circumstances.  

  The pH measurement of the pH 

FUN may be skewed due to an 
external voltage on the pool water. 

  Repeat the check measurement following the 

associated instructions precisely. If ne cessary, use a 
different method for the check measurement. We 
recommend the use of Phenol Red tablets.   

  Perform a pH7 calibration and observe the sequence 

described in Chapter 6 precisely. 
 

 

  Check the earthing of the measuremen t water circuit. 

You will achieve optimum results through two -sided 
earthing both in the measurement water feed as well 
as in the measurement water return. 

9.3 

The pH value in the pool is not correct 

If the displayed pH value on the pH FUN deviates greatly from the check measurement using colour strips or Phenol 
Red tables, please follow the instructions in Chapter 9.2. 

 

 

Cause

 

Remedy

 

The pH value in the 
pool lies above the 
setpoint

 

The pH FUN requires more time to 
adapt the pH value of the pool water 
to the set setpoint. 

Observe whether the pH value gets closer to the 
setpoint. If it does not get sufficiently close, the pH FUN 
triggers a dosing alarm. 

In this case, please observe the appropriate instructions 
in Chapter 9.1. 

The pH value in the 
pool overshoots the set 
setpoint

 

An overdosing of pH-Minus has 
occurred. The dosing rate of the pH 
FUN is too high for the pool, 
particularly in the area of the setpoint. 

Reduce the value of the "Min.dos.rate" parameter (see 
4.3.3 Setting options in

 the menu

) in 3% steps to 

reduce the dosing rate to the proximity of the setpoint 
and thus prevent an overdosing. 

Additionally, you can change the "Dose amount" 
parameter from "normal" to "low" or from "high" to 
"normal" in order to generally decrease the dose 
amount. 

9.4 

The dosing pump is not running 

 

Cause

 

Remedy

 

The pH FUN shows a 
dosing rate of 0% in the 
normal view and the 
dosing pump is not 
running.

 

The pH value of the pool water has 
the reached the setpoint (or lies 
below the setpoint). 

In this case, no additional pH -Minus dosing is required. 
This is thus correct and the dosing pump does not run.  

The pH FUN shows a 
dosing rate of 0% in the 
normal view and the 
dosing pump is not 
running. But the 
displayed pH value lies 
above the setpoint.

 

The dosing of the pH FUN is 
blocked. The following causes are 
possible for this: 

 

No flow 

 

Power-on delay 

 

Level alarm 

 

Dosing alarm 

Switch to the alarm view of the pH FUN to determine the 
cause of the blocking. 
Please observe the information about the different 
alarms in Chapter 9.1 to remedy the blocking. 

The pH FUN shows a 
dosing rate of 0% in the 
normal view 
but the dosing pump is 
not running.

 

It is normal that the dosing pump is 
switched on and off in intervals. 
Depending on the current dosing 
rate, it may only run for several 
seconds per minute under certain 
conditions. (see also Chapter 7.1) 

If the dosing pump does not run at all 
over multiple minutes, the fuse for the 
pump may possibly be defective. 

Replace the fuse for the dosing pump and contact 
BAYROL service if necessary. 

Summary of Contents for pH FUN

Page 1: ...Instructions pH FUN V1 Page 1 of 28 Instruction manual pH FUN...

Page 2: ...ng field of the pH FUN 13 4 1 1 Button functions in the normal view 14 4 1 2 Performing a parameter setting 14 4 2 The pH FUN menu 14 4 3 Setting options of the pH FUN 16 4 3 1 Menu navigation 16 4 3...

Page 3: ...d operated by qualified expert personnel General danger warning Changing the system settings default values can be dangerous to persons under certain circumstances Therefore changes must only be made...

Page 4: ...ok after the disinfection The use of BAYROL algaecide and flocculant products is additionally recommended The product program is perfectly matched to guarantee a perfect water quality with very little...

Page 5: ...ck that the float in the measurement chamber can float freely Adjust the water flow through the cell so that the float just barely lies against the upper end in its guide bore Ensure that connections...

Page 6: ...lowed The equipment should be installed by a licensed electrician The supply voltage for the device may not exceed 240V 50 Hz The allowable operating temperature range is from 0 to 50 O C and the allo...

Page 7: ...to the measurement cell it must be fed directly into the circulating line You will require the following accessories available at your BAYROL dealer 100 509 PE hose length depending on the installatio...

Page 8: ...Measurement water intake 6 Heat exchanger 7 Sand filter 8 Measurement water extractor 9 Circulating pump 10 Container for pH Minus liquid 11 pH Minus suction line 1 pH FUN Chlorine 2 Swimming pool 3 M...

Page 9: ...available Use Europe for all countries not listed Confirm with Pool volume Enter the volume of the swimming pool in m cubic meter using the arrow keys and confirm with The input of the pool volume se...

Page 10: ...Performing the pH7 calib Replace the hoses of the dosing pumps 3 1 1 Checking the hoses Check all hoses for damage e g kinks tears or leakage s contamination e g leaves hair dust or earth and deposits...

Page 11: ...the air from the dosing hose To do so connect pH FUN with the mains and start a manual dosing The purging is complete when you can no longer detect air bubbles on either the suction side canister pum...

Page 12: ...ecautionary measures need to be taken In particular it is very important that the entire system is protected against freezing temperatures and humidity Dosing system Rinse the pump with fresh lukewarm...

Page 13: ...ming a manual dosing The length of time or dose amount of the manual dosing can be set in the menu xx min Remaining time in minutes of a running manual dosing The remaining time is counted down during...

Page 14: ...provides an overview of all important current measurement and control parameters You can also set the operating mode in the normal view of the pH FUN Normally the pH FUN automatically ensures the opti...

Page 15: ...0 min Language German Language German Default Europe Initial operation Menu Normal operation 2 sec 2 sec If an alarm occurs a jump occurs automatically to the alarm display OK confirms all current pen...

Page 16: ...des Auto Man Man and Off are described in the table in section 4 1 Display and operating field of the pH FUN The execution of a manual dosing is additionally described in more detail in Chapter5 Perfo...

Page 17: ...The standard setting should only then be modified when the pH value of the pool water either does not reach the desired setpoint or overshoots the desired setpoint see also Chapter 9 3 The pH value i...

Page 18: ...does not activate as expected the time interval can be adapted accordingly see Chapter 9 1 The pH FUN reports an alarm Danger warning By setting the time interval to 0 minutes the dosing alarm is com...

Page 19: ...or Off You can abort a running manual dosing at any time by resetting the operating mode to Auto or Off 5 1 Calculating the manual dosing The following approximation formula can be used to calculate...

Page 20: ...the pH FUN device beforehand so that the electrode cable does not get twisted when unscrewing the electrode Handle the electrode by its plastic shaft only 5 Rinse the electrode in clean water and the...

Page 21: ...to play when calculating the dosing rate Parameter Explanation Current pH value in the pool water Desired pH setpoint The stronger the currently measured pH value of the pool water deviates from the s...

Page 22: ...m During a dosing alarm Only when the reason for the blocking is no longer present will the pH FUN again enable the dosing When dosing is blocked the pH FUN always shows a dosing rate of 0 in the norm...

Page 23: ...el of the canister in this case is no longer sufficient for an additional dosing the dosing is blocked Replace the empty canister The pH FUN subsequently resumes with the dosing Dosing alarm If the cu...

Page 24: ...f the pool water is too high An overdosing of pH Plus may possibly have occurred Reduce the value of the Min dos rate parameter see 4 3 3 Setting options in the menu in 3 steps to reduce the dosing ra...

Page 25: ...l overshoots the set setpoint An overdosing of pH Minus has occurred The dosing rate of the pH FUN is too high for the pool particularly in the area of the setpoint Reduce the value of the Min dos rat...

Page 26: ...correct measured values The pH7 buffer solution may possibly be contaminated and shows an incorrect pH value The correct sequence for the pH7 calibration may not have been adhered to precisely The pH...

Page 27: ...Level input signal 11 pH input signal 11 12 pH input to the connector of the pH electrode 12 pH input GND 10 2 Replacing the fuses There are 2 fuses on the circuit board No Fuse of Fuse F1 Power supp...

Page 28: ...ller and carefully remove the housing Be careful not to damage the circular seal inserted The fuses are located in a special holder and can be easily replaced The fuse holder is opened using a flat sc...

Reviews: