4 Operating the Salt Relax POWER
24
Range
Unit
Default
Description
0…999
Min.
300
Defines the duration of the cycle for which the chlorine production cell is
switched on to polarity 2.
Although it is possible to set polarity 1 and 2 separately, we recommend
that you set the cycles for both polarities to the same value.
Attention: Setting a time shorter than 200 minutes drastically shortens
the service life and voids the warranty on the chlorine production cell.
0…5
Min.
1
Defines the duration of the dead time (cell is switched off, display of the
output switches to 0) when the polarity of the chlorine production cell is
changed.
A time of at least 1 minute must be set here!
0…999
Min.
1
Only applies if parameter "4 Electrolysis mode" is set to 2:
Defines the wait time after which the additional dosing pump for
disinfection is switched on when the value falls below the selected
setpoint.
0…999
Min.
15
Only applies if parameter "4 Electrolysis mode" is set to 2:
The additional dosing pump for disinfection is switched off even if the
measured value for redox is still below the defined setpoint value after
expiry of this dosing time.
The following can be checked should the system fail to reach the setpoint
within the set time:
-
Redox electrode
-
Setting for output of chlorine production cell
-
Leakage in the dosing line of the additional disinfection
-
The redox setpoint may be too high
0 – 1 - 2
-
1
Only applies if the pH option is installed.
Defines the dosing direction of the Salt Relax POWER:
Setting 0: bi-directional pH regulation
The relay defined in Relay configuration under pH primary
(default: pH)
controls the dosing pump for pH Minus, the
relay defined under pH secondary (default: Aux1)
controls
the dosing pump for pH Plus.
Setting 1: Dosing of pH Minus
The relay defined in Relay configuration under pH primary
(default: pH)
controls the dosing pump for pH Minus.
Setting 2: Dosing of pH Plus
The relay defined in Relay configuration under pH primary
(default: pH)
controls the dosing pump for pH Plus.
0 – 1
-
1
Setting 0: The temperature is not shown on the display.
Setting 1: The temperature is shown on the display. Filter operating
mode Smart becomes available.
0 - 1
1
Setting 0: The relay defined in Relay configuration under Heating
(default: Aux4)
is not temperature-controlled.
Setting 1: The relay defined in Relay configuration under heating
(default: Aux4) is temperature-controlled.
An operating mode which controls the heating (Heating or Intelligent) must
be selected in the Filtration menu.