4 Operating the Salt Relax POWER
10
4
Operating the Salt Relax POWER
4.1
Main screen
4.2
4.2
Quick access to salt electrolysis
The Quick Access function allows rapid activation of the Boost function and easy adjustment of the output of the chlorine production cell.
Electrolysis output
Set the output (large flashing % value) with
/
keys of your Salt Relax POWER. Adjust the system
output to suit the requirements of your pool.
This setting corresponds to the setting in the Electrolysis menu.
Boost
Activate the Boost function by using
/
to select On and confirming with
.
The Boost function increases chlorine production to the maximum value (100%) for the following 24 hours of
filtration time, after which it automatically returns to the programmed filtration cycle. In most cases, this is
sufficient to bridge times of increased chlorine requirement. If Salt Relax Pro is controlled via the external
timer, please ensure that the timer runs continuously for 24 hours.
Note
If your pool needs a chlorine shock, we recommend that you administer it by adding chlorine
manually.
Electrolysis
Production intensity in %
Pol 1 Polarity 1
Pol 2 Polarity 2
Boost function
Measured value
pH / redox (optional)
Status of auxiliary relay
Current time
Status of filtration relay
man Manual
aut Automatic
hea Heating
smt Smart
int Intelligent
Status of lighting
man Manual/ aut Automatic
Cover Production automatically reduced
to %age
Low Missing salt / cell encrusted / cell
spent (see Troubleshooting)
Flow Filtration/production stopped due to
lack of water flow
7.2 pH setpoint
ON/OFF Function settings for the
pH-Minus/pH-Plus pump
AL3 Maximum dosing time exceeded (to
reset the alarm, press
for 5 sec.)
FL1 Flow signal
ON/OFF Function of the additional
chlorine pump (optional)
Tank signal
700 Redox setpoint (minimum value)
Heating ON/OFF
Hold key pressed for
at least 3seconds.