background image

 

We recommend replacing the hose together with the hose 

holder. (Replacement hose set) 

 

Art.-no.  Description 

127402  Replacement hose Flockmatic / Vario S 

127403  Replacement hose set Flockmatic / Vario S 

 

 

NOTE 

If only the hose is replaced, you must strictly 
ensure the following when mounting the hose 

 

Firm seat of the hose on the nozzles. 

 

The hose must not be fitted on twisted under 

any circumstances.  

 

You  must  ensure  that  the  hose  connectors 

are firmly seated..

 

 

4.7

 

Winter care 

For brief interruption of use (e.g. several days) no special 

measures are required. 
For longer interruptions of operation that extend over several 

weeks, as in the case of winter care the following tasks must be 
executed: 
 

 

Remove the suction lance from the canister and rinse it with 
water. 

 

Seal the delivery container, store it in a cool and dry 
location and protect against UV radiation. 

 

Rinse the hose pump with water. 

 

Take the dosing hose out of the pump. 

 

Flush all hoses with water and empty them completely. 

 
After the winter season, all components must be examined to 
determine that they are functional. All dismounted parts must 
be remounted at their intended position. Check the settings of 
the Flockmatic Vario. 

4.8

 

Decommissioning 

If the device will be disposed of after its service life, it must be 
flushed out and the water drained. The device has been 

manufactured in accordance with the provisions of the ROHS 
Directive and the Waste Electrical and Electronic Equipment 
Directive. It does not belong in domestic waste. 

Take the device to a suitable and appropriate collection point. 

5

 

Technical data 

 

Parameter 
 

Value 

Supply voltage 

230VAC 

Power consumption 

max. 20VA 

Ambient temperature 

min.5 - max. 45°C 

Delivery capacity 

2,5 – 600ml/h 

Counterpressure 

max. 3 bar 

Protection class - 
housing 

P65 

Dimensions  

(without mounting plate): 

approx. 93 x 150 x 130 mm 

(WxHxD) 

 

6

 

Spare parts 

 

Art.-No. 
 

Picture 

Description 

127 450   

Flockmatic Vario 

 

172 130   

Suction fitting, rigid PR 

127403   

Replacement hose set 
Flockmatic / Vario S 

 127402   

Pump hose Flockmatic / 
Vario S 

100 509   

PE dosing hose 6x4X1 

(10 m) 

171 207   

Injection nozzle, 0.5 bar 

 

Summary of Contents for Flockmatic Vario

Page 1: ...Flockmatic Vario Version 2 1 GB Operating manual Flocculant dosing pump ...

Page 2: ......

Page 3: ...1 Safety instructions for installation and mintenance tasks 7 4 2 Mounting 7 4 3 Electrical connection 7 4 4 Replacing the device fuse 7 4 5 Installation in the circulation system 8 4 6 Maintenance 8 4 6 1 14 day maintenance 8 4 6 2 Yearly maintenance 8 4 6 3 Cleaning 8 4 6 4 Hose replacement Flockmatic Vario 8 4 7 Winter care 9 4 8 Decommissioning 9 5 TECHNICAL DATA 9 6 SPARE PARTS 9 ...

Page 4: ...lification of personnel Possible consequence Death or severe injury significant damage to material assets The system owner must ensure compliance with the required qualifications All activities must only be carried out by personnel who are qualified to perform such activities Access to the system must be prevented for inadequately qualified personnel IMPORTANT NOTE Compliance with the applicable a...

Page 5: ...states Status Description Off The display is switched off the pump does not display the filling level of the canister for flocculent is not evaluated and no input can be made The green LED flashes at intervals of approx 2 sec Activate the button for approximately 1 second to switch on the device the device is in operating status Off On The green LED flashes briefly at intervals of approx 2 sec the...

Page 6: ...city is set in accordance with the circulation pump used Available languages The device can be configured for multiple languages Acoustic signal The acoustic signal that is triggered when the filling level of the canister for flocculent is low can be activated or deactivated The visual alarm signal will always be output regardless of this setting Output of the alarm via the PoolManager Analyt only...

Page 7: ...r heat conducting pipes or systems Direct sunlight thermal radiation the effects of frost and moisture must be avoided Ensure adequate aeration Ensure that measures are in place in the event of a leak in the pump or the dosing hoses e g defined discharge collecting container The base plate can be used as a drilling template by holding it at the intended location and marking the location of the bor...

Page 8: ...is only use a little water if necessary IMPORTANT NOTE Do not use aggressive cleaners 4 6 4 Hose replacement Flockmatic Vario NOTE Never grease the hose NOTE Only use original spare pump hoses DANGER Danger due to chemicals When pulling off the pump hose corrosive product residues can escape Possible consequence Serious health impairment acid burns and damage to material assets Always empty the pu...

Page 9: ...s with water and empty them completely After the winter season all components must be examined to determine that they are functional All dismounted parts must be remounted at their intended position Check the settings of the Flockmatic Vario 4 8 Decommissioning If the device will be disposed of after its service life it must be flushed out and the water drained The device has been manufactured in ...

Reviews: