59
925.916.2 - GB
InstructIons pertaInInG to the InstaLLer
IMportant:
in the case of conversion from natural gas to propane (LPG), the following operations must be performed
before calibrating the gas valve as illustrated above:
• Turn adjuster screw (V) on the gas valve through the number of complete revolutions specified in table 3 or 3.1;
• On the control panel display set ignition power parameters H608 and H611. The values to be input are given in table 3
or 3.1. The programming methods are described in chapter 17;
To simplify calibration of the gas valve, the “calibration function” can be set directly on the boiler control panel by pro-
ceeding as follows:
1) Press the keys (2-3) together until the display shows the pointer “ ” alongside the symbol (about 6 secon-
ds).
2) Press the keys to set the fan speed at the minimum and maximum heat output (%PWM);
N.b - to set the
minimum
and
maximum
heat output quickly, press the keys respectively;
3) press either of the two keys to exit the function..
0307_2201
Figure 15
Luna3 sYsteM ht 1.240 Mp
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
CO
2
max. heat output
8,7%
10%
CO
2
min. heat output
8,4%
9,5%
CO max
< 250 ppm
< 250 ppm
Gas nozzle
7,5 mm
7,5 mm
Luna3 sYsteM ht 1.180 Mp
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
CO
2
max. heat output
8,7%
10%
CO
2
min. heat output
8,4%
9,5%
CO max
< 250 ppm
< 250 ppm
Gas nozzle
5,7 mm
5,7 mm
table 1c
table 1b
Luna3 sYsteM ht 1.330 Mp
G20 - 2h - 20 mbar
G31 - 3p - 37 mbar
CO
2
max. heat output
8,7%
10%
CO
2
min. heat output
8,4%
9,8%
CO max
< 250 ppm
< 250 ppm
Gas nozzle
12,0 mm
12,0 mm
table 1a