inStructionS Pertaining to the inStaller
15. installation of flue and air ducts
Models 240 Fi - 310 Fi
We guarantee ease and flexibility of instal lation for a gas-
fired forced draught boiler thanks to the fittings and fixtures
supplied (described below).
The boiler is especially designed for connection to an
exhaust flue / air ducting, with either coaxial, vertical or
horizontal terminal. By means of a splitting kit a two-pipe
system may also be installed.
exclusively install fittings supplied by the manufac-
turer.
WarninG :
to guarantee more operating insurance it is necessary
to assure the flue pipes to the wall using the apposite
clamps.
Figure 7
0503_0905/
c
G1638
Figure 8
… coaxial flue - air Duct (concentric)
This type of duct allows to disengage exhaust gases and to draw combustion air both outside the building and in case a
LAS flue is fitted.
The 90° coaxial bend allows to connect the boiler to a flue-air duct in any direction as it can rotate by 360°. It can moreover
be used as a supplementary bend and be coupled with a coaxial duct or a 45° bend.
If the flue outlet is placed outside, the flue-air ducting must
protrude at least 18mm out of the wall to allow alluminium wea-
thering tile to be fitted and sealed to avoid water leakages.
Ensure a minimum downward slope of 1 cm towards the
outside per each metre of duct length.
•
A 90° bend reduces the total duct length by 1 metre.
•
A 45° bend reduces the total duct length by 0.5 me-
tre.
•
The first 90° bend is not included in the maximum avai-
lable length.
securing clamp
concentric outlet
A
B
Boiler
model
250 Fi
310 Fi
0 ÷ 1
1 ÷ 2
2 ÷ 5
0 ÷ 1
1 ÷ 2
2 ÷ 4
Length (m)
air suction
restrictor
B
Yes
No
No
Yes
No
Flue
restrictor
a
Yes
No
No
Yes
No
No
0710_1602
Summary of Contents for Luna 3 Comfort
Page 109: ...109 926 427 1 RU...
Page 113: ...113 926 427 1 RU 3 BAXI 3 2 3 3 1 0609_1901 0609_1902...
Page 114: ...114 926 427 1 RU 4 2 3 1 0605_1802 2 3 2 3 6 OFF 3 3...
Page 115: ...115 926 427 1 RU 3 4 1 3 1 1 1 HW SP 3 4 1 IP PROGR 1 Day 1 7 IP 3 5 prog 3 6 1 4 4 3 6...
Page 120: ...120 926 427 1 RU OFF 3 2 8 6 ERROR 0606_2207 9 7 15 20 5 30 8...
Page 136: ...136 926 427 1 RU 250 Fi 310 Fi 03 9 9 3 9 0 5 3 F17 20 30 5 30 25 9 24 10 24 3 NTC 21...
Page 137: ...137 926 427 1 RU 22 15 9912070100 2 2 3 2 2 23 1 24 2 310 Fi 250 Fi 0603_0303 0603_0304...
Page 141: ...141 926 427 1 RU 30...
Page 143: ...143 926 427 1 RU 32 0711_2806 CG_1980 NTC NTC N R G V B V 25...
Page 257: ...257 926 427 1 GR 3 2 Economy Comfort 0608_3101 3 Comfort 1 0609_1901 0807_1702 CG_2079 1 1 4...
Page 258: ...258 926 427 1 GR 3 2 3 1 0605_1802 2 4 2 COMFORT 3 6 Off 3 3...
Page 265: ...265 926 427 1 GR ERROR E 0606_2207 OFF 3 2 8 6 7 LPG 30 C 5 C 8 9 3 0901_0802 CG_1791...
Page 285: ...285 926 427 1 GR 30...
Page 287: ...287 926 427 1 GR 32 ntc ntc C M N R G V B V 25 0711_2806 CG_1980...