BAXI - 925.200.1
7
GB
HU
CZ
INSTRUCTIONS PERTAINING TO THE USER
925.492.2
9. ERROR MESSAGES AND TABLE OF FAULTS
The anomalies are carried out on the display with an error code (e.g. E01).
The anomalies which can be reset by the user are shown with the symbol (e.g. fi gure 4).
The anomalies which cannot be reset are carried out with the
symbol (e.g. fi gure 4.1).
To RESET the gas boiler, press button for at least 2 seconds.
ERROR CODE
Description of FAULTS
CORRECTIVE ACTION
E01
Gas supply fault
Press the button (fi gure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
E02
Safety thermostat sensor tripped
Press the button (fi gure 1) for at least 2 seconds. If this
fault persist, call an authorised Service centre.
E03
Flue thermostat sensor tripped / Flue pressure
switch tripped
Call an authorised Service centre.
E04
Safety error due to frequent fl ame loss
Call an authorised Service centre.
E05
Central heating NTC sensor fault
Call an authorised Service centre.
E06
Domestic Hot Water NTC sensor fault
Call an authorised Service centre.
E10
Water pressure LOW
Check that the pressure in the system is as specifi ed. See
Section 5. If this fault persist, call an authorised Service cen-
tre.
E11
Safety thermostat for low temperature system
cuts in (if connected)
Call an authorised Service centre.
E25
Boiler max temperature exceeded (probable
pump jammed)
Call an authorized Service centre.
E35
Fault fl ame (parasitic fl ame)
Press the button (fi gure 1) for at least 2 seconds. If this
fault persists, call an authorized Service centre
E97
Electronic board input frequency (Hz) incorrectly
set
Change the frequency (Hz) setting.
E98
Internal card error
Call an authorised Service centre.
E99
Internal card error
Call an authorised Service centre.
10. SERVICING INSTRUCTIONS
To maintain effi cient and safe operation of your boiler have it checked by a Qualifi ed Service Engineer at the end of every
operating period.
Careful servicing will ensure economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily fl ammable cleaners (i.e.: gasoline,
alcohol, and so on). Always isolate the electrical supply to the appliance before cleaning it (see section 6).
Note: when an anomaly occurs, the display background fl ashes with the error code.
Figure 4
6
0
1
1
_
5
0
6
0
Figure 4.1
7
0
1
1
_
5
0
6
0