![Baxi Luna 3 Avant 240 Fi Instructions For The User And The Installer Download Page 23](http://html1.mh-extra.com/html/baxi/luna-3-avant-240-fi/luna-3-avant-240-fi_instructions-for-the-user-and-the-installer_2711795023.webp)
BAXI - 925.200.1
23
GB
HU
CZ
INSTRUCTIONS PERTAINING TO THE INSTALLER
925.492.2
27. ELECTRICAL CONNECTIONS TO A ZONAL HEATING SYSTEM
27.1 CONNECTING THE RELAY BOARD
27.2 CONNECTING THE ZONES
The relay board is not a standard boiler component as it is supplied as an accessory. Connect terminals 1-2-3 (common
- normally closed - normally open) of connector
Cn1
on the relay board to the respective terminals 10-9-8 on the boiler
terminal board
M2
(fi gure 17).
0610_0401 / CG_1840
BOILER BOARD
RELAY BOARD ACCESSORY
Figure 17
Figure 18
ZONE 1
REMOTE CONTROL
ZONE 2
(AMBIENT THERMOSTAT)
ZONE 3
(AMBIENT THERMOSTAT)
ZONE N
(AMBIENT THERMOSTAT)
N
L
Zona 1
Elettrovalvola
M
M
T.A.
2
E.V.2
RE2
M
T.A.
3
E.V.3
RE3
M
T.A.
n
E.V.n
REn
10
9
8
7
6
5
4
3
2
1
C
N.O.
M2
M1
N.C.
1
2
0607_
2801 / CG_182
5
ZONE 1
Connect the contact relative to heating requests in zones that are not controlled by the remote control device in parallel to
terminals 1-2 “TA” on terminal board M1.
Remove the jumper.
The zone controlled by the remote control device is managed by the zone 1 solenoid, as illustrated in fi gure 18.
RELAY 1
RELAY 2
SOLENOID
ZONE 1