INSTRUCTIONS PERTAINING TO THE INSTALLER
925.492.2
20. PARAMETERS SETTING
To set the boiler parameters press the
R
and -
buttons together for at least 6 seconds. When the function is activated,
the display shows “
F01
” alternated with the value of the parameter.
Parameters setting
• Press +/-
buttons for scrolling parameters;
• Press +/-
buttons to change the single parameter value;
• Press the
P
button to save changes, the display shows
“
MEM
”;
• Press the button to leave the function without saving, the
display shows “
ESC
”;
Description of parameter
Default value
F01
Type of gas boiler
10
= sealed chamber
10
F02
Type of gas
00 =
natural (metane)
- 01 =
LPG
00
O
01
F03
Hydraulic system
00 =
instantaneous appliance
00
F04
Programmable relay 1 setting
2 = zone system
(See SERVICE Instructions)
02
F05
Programmable relay 2 setting
13 =
“cool” function for external air-conditioning
system (See SERVICE Instructions)
04
F06
External sensor programmable input setting
(See SERVICE Instructions)
00
F07...F12
Manufacturer information
00
F13
CH max. heating output (0-100%)
100
F14
D.H.W. max. heating output (0-100%)
100
F15
CH min. heating output (0-100%)
00
F16
Maximum temperature setpoint setting
00
= 85°C -
01
= 45°C
00
F17
Pump overrun time
(01-240 minutes)
03
F18
Minimum burner pause
in central heating mode
- 00=10 seconds
03
F19
Manufacturer information
07
F20
Manufacturer information
--
F21...F22
Manufacturer information
00
F23
Maximum D.H.W. setpoint
60
F24
Manufacturer information
35
F25
Lack of water safety device
00
F26...F29
Manufacturer information (read-only parameters)
--
F30
Manufacturer information
10
F31
Manufacturer information
30
F34...F41
Diagnostics (See SERVICE Instructions)
--
Final parameter
Calibration function activation (See SERVICE
Instructions)
00
WARNING: do not modify the values of the “Manufacturer information” parameters.