INSTRUCTIONS PERTAINING TO THE INSTALLER
925.492.2
25. CONNECTION OF THE EXTERNAL PROBE
The boiler is prearranged for connection of an external probe (supplied as accessory).
For the connection, refer to the fi gure below and the instructions supplied with the probe.
When the external probe is connected, the heating
circuit temperature control device regulates the dis-
persal coeffi cient
Kt
. To set the curves (0…90) press the +/-
but-
tons.
NOTE:
the maximum value of the fl ow temperature
TM
depends on the
F16
parameter setting (see sec-
tion 20). The
maximum fl ow temperature it may 85° or 45°C.
Figure 15
CN 5
Graph 2
TM
= flow temperature (°C)
T
e
= e
x ternal temperature (°C)
5
0
3
0
_
3
0
6
0
6
0
3
0
_
3
0
6
0
Graph 3
26. ELECTRICAL CONNECTIONS TO REMOTE CONTROL DEVICE
0610_1302 / CG_1856
CN 7
Figure. 16
(SUPPLIED AS AN ACCESSORY)
The remote control device is not a standard
boiler component as it is su pplied as an
accessory. Open the electronic board and
connect the cable (supplied together with
the two-pin terminal board) to connector
CN7 on the electronic boiler board. Con-
nect the terminals of the remote control
device to the two-pin terminal board (fi gure
16).
Kt curves