spillage check again.
Fit the restrictor as shown in figure 11 using the two screws provided.
9. FIREBOX INSTALLATION
9.1 Firebox installation.
1.
Make sure that the relevant areas at
the fireplace back are sound enough
to take the eyebolts. If these areas
have deteriorated due to prolonged
use they should be made sound with a
suitable cement.
2.
Drill two holes in the rear wall of
the fireplace for the eyebolt plugs.
The holes should be drilled within the
range of positions shown in figure 12
using a no.12 masonry drill. The
holes should be equidistant each side
of the centre line of the fireplace to
ensure that the appliance finishes
centrally in the opening when tension
is applied to the cables.
3.
Insert a fibre plug into each hole.
Use the fibre plugs supplied with this
appliance -
Never use plastic plugs
instead of the fibre plugs supplied
.
Screw the eyebolts into the plugs.
Make sure that the eyebolts are
secure.
4.
Place the convector box unit close
to the fireplace but allow sufficient
access into the fireplace opening so
that the cables can be threaded
through the eyebolts and returned
through the back of the convector box. If a concealed connection is being used, insert
the convector box into the fireplace feeding the supply pipe through the pierced hole in
the rear grommet.
Page 17
INSTALLER GUIDE
Figure 12. Eyebolt positions