Remove all the items carefully to prevent damage. Take special care when handling the
ceramic components. Some items may be contained in the packaging fitments -
Examine the packaging carefully before discarding. Check that all the items are present
and undamaged.
5. FIREPLACE CHECK
5.1 Fireplace check.
5.1.1 Fireplace size
The fireplace must comply with the requirements described in section 3.2. This may
entail removing the fireback and infill material behind the fireback.
5.1.2 Fireplace general condition
The fireplace floor should be reasonably flat to ensure that the convector box can be
installed without it rocking and so that a good seal can be made at the bottom front of
the box. The front face of the fireplace should be reasonably flat over the area covered
by the convector box top and side flange seals to ensure good sealing. These faces
should be made good if necessary. If the appliance is to be fitted against a wall with
combustible cladding, the cladding must be removed from the area covered by the
Page 13
INSTALLER GUIDE
Figure 6. Pack contents