Current measurement
KSG 200 A/KSG 200 TA
44 / 60
822-170-3
DANGER
Dangerous voltage in cable that is to be identified
Danger to life or risk of injury due to electric shock.
Do not use the current measurement with KSG 200 A/KSG 200 TA
to determine that the cable is disconnected.
If no current can be ascertained in the cable by measuring with KSG
systems, it does not mean that the cable is disconnected and can be
safely cut.
With KSG 200 A/KSG 200 TA, you can measure current (50/60 Hz) up to 199 A on the
connected cable.
1. To measure the current on the cable that is to be identified after calibration, press the
button.
If you want to measure current without prior calibration, press the
button twice.
The receiver displays the following:
Standard mode: If an infocode is available for the current measurement situation, the
infocode is displayed first. Finally, the rms value of the current is displayed.
Expert mode: The rms value of the current is displayed. To display any existing
infocode, press the
button once again.
The current measurement is completed automatically after many measurement cycles. If a
value above 199 A is measured, the display flashes the number 199.
2. To manually complete the current measurement, press the
button.
8
C
URRENT M EASUREMENT