Installation
Manual
b maXX
®
BM1000
Document No. 5.07003.04
55
6
Items
Explanations
Power supply
Please follow the specific power supply requirements shown in
Fuse/protective fuse
breaker (optional)
There may be an inrush current during power up. Please check the chart of
B.4 Fuses for device-protection
132 to select the correct fuse. Use of an protective fuse breaker is optional.
Magnetic contactor
(optional)
Please do not use a magnetic contactor to switch on/off the
b maXX
®
BM1000
during device operation, as it will reduce the operating life cycle of the device.
Mains choke (optional)
Used to improve the input power factor, to reduce harmonics and provide protec-
tion from mains interferences. (surges, switching spikes, short interruptions, etc.).
The mains choke should be installed when the power supply capacity is 500 kVA
or more and exceeds 6 times the device capacity, or the mains wiring distance
≤
10 m. See
6.15 Applications for mains chokes
on page 130 for further information.
Additional EMC filter
(optional)
To reduce electromagnetic interference.
NOTE
The models b maXX
®
1000 have an built-in EMI filter. An additional mains filter is
necessary for cable lengths > 15 m (cable device - motor).
For further information see
Chopper unit/
braking resistor
(optional)
Used to reduce the deceleration time of the motor.
m
Frame 1:
No built-in chopper unit:
Use of chopper unit and braking resistor necessary (refer to
chopper unit /braking resistor
m
Frame 2 and 3:
Built-in chopper unit:
Connection of a suitable braking resistor (see
from page 120) possible.
If the motor generates additional regeneration energy a further chopper unit
with braking resistor can be connected.
Output choke (optional)
Motor surge voltage amplitude depends on motor cable length.
For applications with long motor cable, it is necessary to install a choke at the
device output side.
230V 1-phase:
0,4 kW and smaller: max 15 m.
0,75 kW and higher: max 50 m.
400V 3-phase:
0,75 kW and smaller: max 20 m.
1,5 kW and higher: max 50 m.
For more information see
Summary of Contents for b maXX BM1000
Page 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Page 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Page 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Page 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Page 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Page 175: ......