Maintenance
Manual
b maXX
®
BM1000
Document No. 5.07003.04
105
9
m
Transformer and chokes of main circuit
m
Magnetic contactor and relay of main circuit
m
Printed circuit board and connector of main circuit
m
Cooling fan of cooling system
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there is any abnormal vibration or peculiar
smell
Visual, aural inspection and smell
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there are any loose screws
Visual and aural inspection. Tighten screw if neces-
sary
O
If the contact works correctly
Visual inspection
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there are any loose screws and connectors
Tighten the screws and press the connectors firmly in
place.
O
If there is any peculiar smell and color
change
Visual inspection and smell
O
If there is any crack, damage, deformation or
corrosion
Visual inspection
O
If there is any leaked liquid or deformation in
capacitors
Visual inspection
O
Check items
Methods and criterion
Maintenance period
Daily
Half
year
One
year
If there is any abnormal sound or vibration
Visual, aural inspection and turn the fan with hand
(turn off the power before operation) to see if it rotates
smoothly
O
If there is any loose screw
Tighten the screw
O
If there is any change of color due to over-
heating
Change fan
O
Summary of Contents for b maXX BM1000
Page 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Page 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Page 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Page 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Page 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Page 175: ......