Technical data
Manual
b maXX
®
BM1000
Document No. 5.07003.04
143
D
D.3
Electrical data
Voltage
230 V series
BM
1211
1212
1213
1224
1225
Max. applicable motor output
(kW)
0.2
0.4
0.75
1.5
2.2
Ou
tp
ut
rat
in
g
Rated output capacity (kVA)
0.6
1.0
1.6
2.9
4.2
Rated output current (A)
1.6
2.5
4.2
7.5
11.0
Maximum output voltage (V) 3-phase proportional to input voltage
Output frequency (Hz)
0.1 to 600 Hz
Carrier frequency (kHz)
1 to 15
Input rating
Rated input current (A)
single
4.9
6.5
9.5
15.7
24
Rated voltage/frequency
single
200 to 240 V, 50/60 Hz
Voltage tolerance
±
10 % (180 to 264 V)
Frequency tolerance
±
5 % (47 to 63 Hz)
Cooling method
natural cooling
fan cooling
Voltage
460 V series
BM
1412
1413
1414
1425
1426
1437
1438
1439
Max. applicable motor output
(kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
Ou
tp
ut
r
a
ti
ng
Rated output capacity (kVA)
1.2
2.0
3.3
4.4
6.8
9.9
13.7
18.3
Rated output current (A)
1.5
2.5
4.2
5.5
8.2
13
18
24
Maximum output voltage (V)
3-phase proportional to input voltage
Output frequency (Hz)
0.1 to 600 Hz
Carrier frequency (kHz)
1 to 15
Input rating
Rated input current (A)
3-phase
1.9
3.2
4.3
7.1
11.2
14
19
26
Rated voltage/frequency
3-phase, 380 to 480 V, 50/60 Hz
Voltage tolerance
±
10 % (342 to 528 V)
Frequency tolerance
±
5 % (47 to 63 Hz)
Cooling method
natural
cooling
fan cooling
Summary of Contents for b maXX BM1000
Page 1: ...E 5 07003 04 Manual b maXX BM1000 Basic unit ...
Page 108: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 108 of 174 ...
Page 118: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 118 of 174 A ...
Page 172: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 172 of 174 Index ...
Page 174: ...Manual b maXX BM1000 Document No 5 07003 04 Baumüller Nürnberg GmbH 174 of 174 Notes ...
Page 175: ......