en_BA_OM70_multi-spot.docx
8/60
Baumer Electric AG
04.01.2021 14:26/tof V1.2 ANW_81156398
Frauenfeld, Switzerland
3
Connection
3.1
Connection cable
An 8-pole, shielded connection cable (connector) is required.
Baumer connection cables with the following order codes are recommended:
10127844
ESG 34FH0200G (length 2 m, straight plug)
11053961
ESW 33FH0200G (length 2 m, angled plug)
10129333
ESG 34FH1000G (Länge 10 m, straight plug)
10170054
ESW 33FH1000G (Länge 10 m, angled plug)
Other cable lengths are available.
When using the analogue output, the cable length has an influence on the signal noise. The longer the cable,
the greater the signal noise.
Analog output I_OUT
Noise: 5.92 uA (1 Sigma) (10 m cable and 680 ohm)
3:59 uA (1 sigma) (2m cable and 680 ohm)
Analog output U_OUT
Noise: 4.80 mV (1 Sigma) (10m cable and 100 kOhm)
3:03 mV (1 Sigma) (2m cable and 100 kOhm)
For high-precision applications, the use of the RS485 interface is recommended.
ATTENTION!
Laser class 1 laser beam according to EN 60825-1:2007. This product can be
operated safely without any additional safety precautions. Nevertheless direct
contact between the eye and beam should be avoided.
ATTENTION!
The IP protection class is valid only if all connections are connected as
described in the technical documentation.
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel.
ATTENTION!
Incorrect supply voltage will destroy the device!