![Baumer OM70 Operating Instructions Manual Download Page 10](http://html.mh-extra.com/html/baumer/om70/om70_operating-instructions-manual_2710818010.webp)
en_BA_OM70_multi-spot.docx
10/60
Baumer Electric AG
04.01.2021 14:26/tof V1.2 ANW_81156398
Frauenfeld, Switzerland
4
Installation
4.1
Mounting
The sensor has four mounting holes for flexible alignment and mounting. The use of 2 M4x35 screws is
recommended for mounting. The tightening torque is max. 1.2 Nm.
4.2
Sensor reference levels
The sensor can be aligned with the following levels:
The laser beam of the sensor runs parallel ( // ) to level R3 and is at a right angle to levels R1 and R2. Levels
R1, R2, and R3 serve as references for sensor alignment during installation. "Left" and "Right" designations
are also important.
19
m
m
Level R3
Laser
beam
Level R1
Level R2
13 mm
Tightening torque
max. = 1.2 Nm
ATTENTION!
Connection, installation and commissioning may only be performed by qualified
personnel. Protect optical surfaces from moisture and dirt.
Left
Right