6.6.1.1
Formulas for analog signal conversion
The measuring values can be converted from mm into the analog output signal and vice versa with the
following formulas.
If the measuring range has been limited with SCALE OUT, the new settings for
Current Start of measuring
range Sdc
and
Current End of measuring range Sde
must be used.
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝑽 =
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝒎 − 𝑆𝑑𝑐
𝑆𝑑𝑒 − 𝑆𝑑𝑐
∗ 10𝑉
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝑨 =
16 𝑚𝐴 ∗ (𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝒎 − 𝑆𝑑𝑐)
𝑆𝑑𝑒 − 𝑆𝑑𝑐
+ 4 𝑚𝐴
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝒎 =
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝑨 ∗ (𝑆𝑑𝑒 − 𝑆𝑑𝑐) + (20 𝑚𝐴 ∗ 𝑆𝑑𝑐) − (4 𝑚𝐴 ∗ 𝑆𝑑𝑒)
16 𝑚𝐴
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝒎𝒎 =
𝑴𝒆𝒂𝒔𝒖𝒓𝒊𝒏𝒈 𝒗𝒂𝒍𝒖𝒆 𝒊𝒏 𝑽 ∗ (𝑆𝑑𝑒 − 𝑆𝑑𝑐) + (10 𝑉 ∗ 𝑆𝑑𝑐)
10 𝑉
DISTANCE function definitions
E
n
d
o
f
m
e
a
su
ri
n
g
r
a
n
g
e
S
d
e
S
ta
rt
o
f
m
e
a
su
rin
g
ra
n
g
e
S
d
c
0 V / 4 mA
10 V / 20 mA
HINWEIS
Sdc and Sde are always in mm.