8
|
Technical data
Baumer Hübner
46
Operating Manual
HMG10 & HMG10P SSI | V1, T1
8
Technical data
HMG10
Electrical Data
Voltage supply Ub
4,75-30 V DC
Short-circuit proof
Yes
Operating current without load
≤ 100 mA
Initializing time
≤ 500 ms after switch-on
Sensing principle
Magnetic
Fieldbus interface
SSI
Steps per turn
1048576 / 20 Bit
Number of turns
1048576 / 20 Bit
Incremental output
Rectangle TTL/HTL, TTL/RS422
Code
Gray (factory setting) or binary
Code pattern
CW (default)
Input signals
SSI Clock, PRESET, Direction of rotation
Interference immunity
see data sheet and declaration of conformity
Interference emission
see data sheet and declaration of conformity
Programming interface
RS485 (≤ 600 m)
I
Programmable parameters
Resolution Singleturn and Multiturn (SSI)
I
, Bi-
nary or Gray Code (SSI)
I
Additional output (ppr number)
I
Switch off / on speed
I
Diagnostic functions
Function monitoring
LED status indicator
4 LEDs at rear of the device
Approvals
see data sheet and declaration of conformity
Electrical data (Speed switch)
Switching accuracy
±2 % (or 1 digit)
Switching outputs
1 output
(Open-collector
II
or semiconductor relay
II
)
Output switching performance
30 V DC; ≤ 100 mA
Switching delay
≤ 20 ms
Mechanical
Dimensions (flange)
ø 105 mm
Shaft type
HMG10-B
ø 16...20 mm (blind hollow shaft)
ø 17 mm (cone shaft 1:10)
HMG10-T
ø 16...20 mm (through hollow shaft)
Flange
Torque plate, in any position throughout 360°
Protection class DIN EN 60529
IP66/IP67