6
|
Electrical installation
Baumer Hübner
36
Operating Manual
HMG10 & HMG10P SSI | V1, T1
6.9.3
Assignment second flange connector
NOTICE
Operating voltage present at the outputs results in encoder damage.
The encoder might be damaged by any operating voltage being present at the outputs.
a) Make sure that no operating voltage is present at the outputs.
Additional output incremental 2 (optional)
Speed switch (optional)
The TTL/HTL output (Vin = Vout) at the additional output incremental 2 is galvanically isolated
and requires separate voltage supply.
1
2
3
4
5
6
7
8
9
10
12
11
Ill. 9:
Flange socket M23 (male, 12-pin, clockwise)
PIN
Assignment
PIN
Assignment
1
dnu / B−
I
7
dnu / SP+
II
2
nE−
8
dnu / B+
I
3
dnu / R+
I
9
dnu / SP−
II
4
dnu / R−
I
10
0V
I
5
dnu / A+
I
11
nE+
6
dnu / A−
I
12
Ub 3)
I
I
Additional output incremental (optional)
II
Speed switch (optional)