Baumer Hübner
Electrical installation
|
6
V1, T1 | HMG10 & HMG10P SSI
Operating Manual
29
6.6
LED activity indicator
LED
red
green
INC1 (additional output incre-
mental 1)
n
Undervoltage
n
Overload
n
Excess temperature
OK
INC2 (additional output incre-
mental
n
Undervoltage
n
Overload
n
Excess temperature
OK
Status
Internal error
OK
Speed
Speed higher than switching
speed (overspeed)
Speed below switching speed
Tab. 2:
LED activity indicator
6.7
Output switching behavior Speed switch (optional)
INFO
Default switching speed is 6000 rpm for HMG10P and PMG10P. HMG10 and PMG10 without
programming interface come with the individually ordered permanent switching speed.
Event
Speed switching output state
During initialization
High-impedance (overspeed)
After initialization and speed being ≤ -ns (off)
High-impedance (overspeed)
-ns (off) < speed ≤ -ns (on)
Status unchanged
Device rotation within this speed range during
initialization results in status low-impedance
(no overspeed) after initialization
-ns (on) < speed ≤ +ns (on)
Low impedance (No overspeed)
+ns (on) ≤ speed < +ns (off)
Status unchanged
Device rotation within this speed range during
initialization results in status low-impedance
(no overspeed) after initialization
+ns (off) ≤ speed
High-impedance (overspeed)
n
= Speed
+ns
(off)
= Switch-off speed at shaft rotation in positive rotating direction*
-ns
(off)
= Switch-off speed at shaft rotation in negative rotating direction*
Switching hysteresis : 10...100 % (factory setting = 10 % min. 1 Digit)
+ns
(on) = Switch-on speed at shaft rotation in positive rotating direction*
-ns
(on) = Switch-on speed at shaft rotation in negative rotating direction*
Low resistance
Resistance between
SP+ and SP-
High resistance
-ns (on)
0
+ns (on)
-n
+n
-ns (off)
+ns (off)