30
Baumer Ident
OIS-P, PC3141/03 Manual
Installation
6.2.4 Test terminal
The test terminal is connected to TERMINAL, see
Figure 6.10. TERMINAL is a male 9 pin D-Sub
connector.1500AO. Use cable connector D-Sub 9
female.
Figure 6.10 Test terminal connection
6.2.3 Antenna connection
The central unit PC3141/03A uses a separate
antenna conntected to ANTENNA according to
figure 6.9. ANTENNA is a D-Sub 9 female connector.
Figure 6.9 Antenna connection
For order codes of antenna connection cables, see
section 1.2.
The connection to the antenna must be done with a
shielded cable.
Figure 6.7
Current loop passive transmitter
Figure 6.8
Current loop passive receiver
HOST
CLI+
CLI-
CLO B
CLO A
ANTENNA
PC3141/03
GND
RESERVED IN
RESERVED IN
PF–
EN+
+18V
RESERVED OUT
PF+
EN–
1
2
3
4
5
6
7
8
9
RESERVED
RxD
TxD
GND
RTS (NOT USED)
CTS (NOT USED)
1
2
3
4
5
6
7
8
9
TERMINAL
PC3141/03
When the test terminal is not connected, the
contact must be protected with the cover.
This connection is only intended for test purpose
and is not optoisolated. This means that it should
be used with care, e.g. with a short, shielded cable
and should not be permanently connected.
The terminal can also be used to examine the list of
the most recent error codes, host communication
messages and to test the communicator to a Data
Tag.
HOST
4
12
9
1
{
{
{
{
{
{
{
{
{
{
Summary of Contents for OIS-P PC 3100 series
Page 2: ...Page intentionally blank ...
Page 4: ...4 Baumer Ident OIS P PC3141 03 Manual Page intentionally blank ...
Page 6: ...6 Baumer Ident OIS P PC3141 03 Manual Page intentionally blank ...
Page 12: ...12 Baumer Ident OIS P PC3141 03 Manual System description Page intentionally blank ...
Page 24: ...24 Baumer Ident OIS P PC3141 03 Manual Health aspects Page intentionally blank ...
Page 26: ...26 Baumer Ident OIS P PC3141 03 Manual Page intentionally blank Maintenance aspects ...
Page 42: ...42 Baumer Ident OIS P PC3141 03 Manual Page intentionally blank ...