o
A hose length of 0.9m to 1.25m is recommended. The length of
hose chosen should be such that when the cooker is in situ, the
hose does not touch the floor.
o
Care should be taken to ensure that the temperature rise of areas
at the rear of the cooker that are likely to come in contact with the
flexible hose do not exceed 70°C.
o
Gas pressure may be checked on a semi-rapid hob burner. Remove
the appropriate injector and attach a test nipple. Light the other
burners and observe that the gas pressure complies with the gas
standards in force.
o
This cooker can be connected to the supply both on the right and
left hand side at the rear of the cooker. To reverse the position,
remove the blanking plug and refit it to the opposite side to where
the hose is being connected.
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan-stands, burners and flame
spreaders (A).
34
gas supply
(see table below).
particular you should make sure that the
o
Unscrew the injector (B) and replace it with
the stipulated injector for the new
o
Reassemble all the burners carefully; in
flame spreader is correctly placed on the
burner.