Gas Safety (Installation and Use) Regulations
o
It is the law that all gas appliances are installed by competent
persons in accordance with the current edition of the Gas Safety
Installation and Use Regulations.
o
It is in your interest and that of safety to ensure compliance with
the law.
o
In the UK, GASSAFE registered installers work to safe standards of
practice. The cooker must also be installed in accordance with the
current edition of BS 6172. Failure to install the cooker correctly
could invalidate the warranty, liability claims and lead to
prosecution.
o
IMPORTANT: It is a requirement for a stability chain to be
fitted to the appliance. Please see page 28 for more detailed
information on this.
Gas connection
ALL INSTALLATION AND SERVICE WORK MUST BE
CARRIED OUT BY A GASSAFE REGISTERED
ENGINEER.
o
Prior to installation, ensure that the gas supply conditions (nature
of the gas and gas pressure) and the adjustment conditions are
compatible. The adjustment conditions for this appliance are stated
on the rating plate which can be found on the back cover.
o
This appliance is not designed to be connected to a combustion
product evacuation device. Particular attention should be given to
the relevant requirements regarding ventilation.
o
IMPORTANT: THE FIBRE WASHERS MUST BE IN PLACE WHEN
CONNECTING THE ADAPTOR ELBOW.
o
Connect the short transition pipe to the elbow, inserting the
washer. Connect the brass adapter with the test point to the nut of
the transition pipe, inserting the washer. Then fix the retention
device with the screw.
o
Connection to the cooker should be made with an approved
appliance flexible connection to BS
669.
o
If the cooker has been converted for use with LPG, then it should be
connected to the gas supply using an appropriate bayonet type
hose. The hose MUST be suitable for use with LPG gas, these are
identifiable by a red band or stripe.