33
o
Unscrew the injector and replace it with the
stipulated injector for the new gas supply
(see table below).
Rater
capacity
Power
(kW)
Burner
Types of
gas
Pressure
(mbar)
Nozzle
diameter
(1/100 mm)
g/h
l/h
Max. Min.
Natural
(G20)
20
72
-
95
Butane
(G30)
30
50
73
-
Auxiliary
Propane
(G31)
37
50
71
-
1.00 0.48
Natural
(G20)
20
97
-
167
Butane
(G30)
30
65
127
-
Semi-
rapid
Propane
(G31)
37
65
125
-
1.75 0.60
Natural
(G20)
20
115
-
286
Butane
(G30)
30
85
254
-
Rapid
Propane
(G31)
37
85
250
-
3.00 1.05
Natural
(G20)
20
135
-
286
Butane
(G30)
30
95
218
-
Wok
Propane
(G31)
37
95
214
-
3.50 1.80
o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section on the next page.