Operation
49
4.2 Starting Up
The following starting/stopping procedure is a simple example (not binding) and it‟s based on a
simple starting control panel equipped with starting key. Please refer to the genset and/or
genset control panel use & maintenance manual for the starting operation mode.
Before starting the engine, operate the
stop control lever to ensure flexible
motions, and the crankshaft can rotate
smoothly.
Turn the key to position “1” to power on
the control panel. The “oil pressure
warning lamp" automatically will turn on
for 10s. It‟s recommended to test the
indicator lamps, bulbs, and buttons
once (by pressing the touch button on
the control panel).
Turn the key to position “START” to
start the engine and then release the
key. The key will automatically return to
position “1”.
Figure 4.2-Switch
NOTE
When starting, if the engine fails to start within 10s, immediately release the button and
wait for 1min. before retry.
If the engine can‟t start after three consecutive attempts, stop and solve the malfunction
before retry.
During the working of engine, the “oil pressure warning lamp” and the "battery power”
indicator lamps are all off.
All indicator lamps are off during normal running of engine.
In event of abnormality, the “horn” will issue warning sound.
The assistant devices shall be used to start the engine under cold temperature.