background image

 

 

USER MANUAL 

Thank you for buying BC PRO 4S, the new professional 
battery charger & tester BC with 4 units, featuring an 
automatic 8-cycles charging technology and suitable for 
the care of all 12V lead-acid batteries in workshop. 
BC PRO 4S is ideal both for the maintenance of used 
batteries and for the initialization of new batteries. 
Moreover, the unit with LCD also features a selectable 
charging program for LiFePO4 batteries (7 steps + POLAR 
Mode for safe charging by low ambient temperatures). 

 
CONTENT OF THE PACKAGE 

1.

 

Battery Charger & Tester BC PRO 4S 

2.

 

Power supply cable. 

3.

 

4 connectors with insulated clamps (code 30AMPPZ). 

4.

 

Copy of this manual. 

 

FUNCTIONS 

-

 

4-banks battery charger (1 unit with LCD display, 3 
units with LED bar): 

 

 
          Output unit 
          with LCD display 
          (charge & test) 
 
          3 outputs units  
          with LED bars 
 

-

 

Test of the battery and the vehicle’s charging system 

 
CHARGE 

You can charge up to 4 batteries at the same time. 

To recharge batteries, please follow the steps below

1.

 

Connect the device to the 220V power outlet 

2.

 

Turn on the switch on the back of BC PRO 4S 

3.

 

Connect the batteries to the outputs of BC PRO 4S 
through the included insulated clamps 

UNIT WITH LCD - CHARGING PROGRAM SELECTION 
To change the charging program (lead/acid or LiFePO4), 
keeping the clamps in short circuit, turn on and turn off 
the device

. The selected program is shown on the 

display and kept in memory. 

 

CHARGE - UNIT WITH LCD DISPLAY - MESSAGES 

The display shows the charging cycle executed, the 
battery voltage (digital voltmeter) and an estimate of the 
battery state of charge (1 to 5 bars) in real time. 

 

       

 

 

Possible occurring anomalies are indicated by the device 
as follows: BC not connected to 220V, Battery not 
connected, Battery Inversion of Polarity. 

 

CHARGE - UNITS WITH LED BAR - MESSAGES 

 

RED LED - ERROR MESSAGES 

 

- Steadily lit: 220V input power missing (or device off) 
- Slowly blinking: battery not connected to the unit 
- Swiftly blinking: polarity inversion, short circuit or 

empty/irrecoverable battery 

 

RED LED + GREEN LED - BATTERY ANALYSIS FAILED 

If the battery analysis gives a negative result, the red and

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

green LEDs blink alternatively: the battery is not able to 
retain the charge, it may be necessary to substitute it. 
 

GREEN LED – REGULAR WORKING CONDITIONS 

 

- Recovery & charging phases: 

 

The greed LED blinks slowly 

 

The 4 LEDs that make up the LED bar below light up 
in sequence from bottom to top: when the yellow 
LED “100%” turns on, the battery is fully charged 

- Desulfation phase: 

 

The green LED blinks swiftly 

 

The yellow LED “100%” is steadily lit 

 

The 3 LEDs below light up in sequence from bottom 
to top, to indicate the time-to-end for the desulfation 
phase (less than 9 hours, 6 hours or 3 hours). 

- Maintenance phase: 

 

The green LED is steadily lit 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FAST BATTERY CHARGING -TURBO MODE 

 

In order to reduce the charging time, you can exploit the 

TURBO MODE

 of BC PRO 4S, connecting more than one unit 

of the device to the same battery. It is highly recommended to observe the limits indicated in the following table 
according to the battery capacity/code. The table is also reported on the device itself. 

 

INITIALIZATION OF NEW BATTERIES 

 

At the end of the Bulk Charge (phase 4), when the yellow LED 
“100%” is on or the LCD display shows the message “Battery 
in… Desulf.”, the battery is ready for use: disconnect it

 

RECOVERY & CHARGING OF USED BATTERIES 

 

At the end of the Bulk Charge (phase 4), we recommend to 
execute the entire cycle of desulfation, which allows a better 
reconditioning of batteries with a mild/medium sulfation

 

BC PRO 4S - WHAT DO I NEED TO DO? INDICATIONS FOR USE 

Summary of Contents for BC PRO 4S

Page 1: ...corrimento batteria non collegata BC non collegato a 220V cavo invertito o corto circuito RICARICA UNIT CON BARRA LED MESSAGGI LED ROSSO MESSAGGI D ERRORE Acceso fisso dispositivo non collegato a 220V...

Page 2: ...ella batteria all avviamento del veicolo 3 Test del sistema di carica alternatore regolatore Nota bene durante l esecuzione dell intera procedura di test non sar possibile utilizzare le altre postazio...

Page 3: ...ento alla Scheda Tecnica sul presente manuale MANUTENZIONE Per assicurare un funzionamento ottimale si consiglia di controllare il corretto fissaggio dei morsetti alla batteria e di rimuovere eventual...

Page 4: ......

Page 5: ...220V Battery not connected Battery Inversion of Polarity CHARGE UNITS WITH LED BAR MESSAGES RED LED ERROR MESSAGES Steadily lit 220V input power missing or device off Slowly blinking battery not conn...

Page 6: ...ery voltage at rest 2 Test of the battery cranking power 3 Test of the charging system alternator regulator Please note that while executing the testing procedure it s not possible to use the other un...

Page 7: ...ressed MAINTENANCE In order to ensure a regular functioning it is suggested to periodically check the correct and stable connection of the clamps to the battery and to remove dust and oil from the bat...

Page 8: ......

Page 9: ...cran LCD montre les messages d erreur batterie pas branch BC n est pas branch la prise 220V polarit invers e ou court circuit CHARGE UNIT S AVEC LEDS MESSAGES LED ROUGE MESSAGES D ERREUR Toujours allu...

Page 10: ...de la proc dure de test ne peut pas tre utilis d autres stations chargeur BC Pro 4S doit tre teint d branch du r seau 220V FONCTIONNEMENT MODE TESTEUR 1 Test tension de batterie au repos mesure et cal...

Page 11: ...LA AGM Gel Ca Ca Pour obtenir des indications sur la capacit des batteries recharger se r f rer s il vous pla t la section Caract ristiques Techniques du manuel ENTRETIEN Pour garantir une fonctionnal...

Page 12: ......

Page 13: ...terie nicht verbunden BC nicht verbunden mit 220V Vorzeichenumkehr oder Kurzschluss AUFLADUNG AUSG NGE MIT LED LEISTE ANZEIGEN ROTE LEUCHTDIODE FEHLERMELDUNGEN St ndig an das Ger t ist an 220V nicht v...

Page 14: ...C Pro 4S muss ausgeschaltet bleiben BETRIEBS TESTGER T 1 Test des Batterieladezustands in Ruhe das Ger t misst und berechnet die mittlere Batteriespannung Anweisungen um ein signifikantes Ergebnis zu...

Page 15: ...rh ltlichen 12V Blei S ure Batterien Nassbatterien MF AGM VRLA und GEL Batterien und 12V LiFePO4 Batterien entworfen Lesen Sie bitte die Tabelle Technische Daten f r Hinweise ber die Batteriekapazit t...

Page 16: ......

Page 17: ...uales anomal as desplazando los mensajes bater a no conectada BC no conectado a 220V cable invertito o corto circuito RECARGA UNIDAD CON BARRA LED MENSAJES LED ROJO MENSAJE DE ERROR Encendido fijo BC...

Page 18: ...l arranque 3 Test del sistema de carga alternador regulador Cuidado durante todo el procedimiento de test no ser posible utilizar las otras salidas del cargador de bater as BC Pro 4S no tiene que ser...

Page 19: ...ara informaciones sobre la capacidad de las bater as que se deben recargar consultar la Ficha T cnica de este manual MANUTENCI N Para garantizar un funcionamiento optimal es aconsejado controlar el co...

Page 20: ......

Reviews: