Configuring the Camera
BASLER L800
k
4-35
Draft
Area of Interest Length CSR
Register Base Address:
0x100A
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this control register:
0x00 = The register is not available
0x01 = The register is available. All related settings are OK
0x80 = A value in the register is set out of range
0X81 = The setting for the AOI length conflicts with the setting for the AOI starting pixel.
Field Name:
Length
Offset:
0x0001
Size:
2 Bytes
Type:
Read / Write
Description:
Writing an integer value to this field sets the length in pixels for the area of interest (AOI)
feature. The value for the length in pixels can normally range from 2 (0x0001) to 8160
(0x1FE0). The actual available range may be limited by the way any related parameters
are set.
If the value is set to 2, the length of the AOI will be 2 pixel. If the value is set to 4, the length
of the AOI will be 4 pixels. Etc.
(The AOI Length must be set to an even number, i.e., 2, 4, 6, 8, etc.)
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the length value
Byte 2 = High byte of the length value
See Section
for more information about the AOI feature.
Field Name:
Min
Offset:
0x0003
Size:
2 Bytes
Type:
Read only
Description:
Minimum allowed integer value for the length setting. This field is updated to reflect limita-
tions caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = High byte of the min value
Field Name:
Max
Offset:
0x0005
Size:
2 Bytes
Type:
Read only
Description:
Maximum allowed integer value for the length setting. This field is updated to reflect limita-
tions caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = High byte of the max value
Field Name:
Increment
Offset:
0x0007
Size:
2 Bytes
Type:
Read only
Description:
An integer value indicating the increment for the length setting.
The 4 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = High byte of the max value
Summary of Contents for L800k
Page 4: ......
Page 10: ...Contents VI BASLER L800k Draft...
Page 23: ...Camera Interface BASLER L800k 2 7 Draft Figure 2 3 Camera Frame Grabber Interface...
Page 40: ...Camera Interface 2 24 BASLER L800k Draft...
Page 152: ...Mechanical Considerations 5 6 BASLER L800k Draft...
Page 166: ...Feedback iv BASLER L800k Draft...