Configuring the Camera
BASLER L800
k
4-27
Draft
Field Name:
Raw Min
Offset:
0x000F
Size:
2 Bytes
Type:
Read only
Description:
Minimum allowed integer value for the raw offset setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the min value
Byte 2 = High byte of the min value
Field Name:
Raw Max
Offset:
0x0011
Size:
2 Bytes
Type:
Read only
Description:
Maximum allowed integer value for the raw offset setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = High byte of the max value