GB - 20
GENERAL RECOMMENDATIONS
For correct use of the spike probe:
- avoid violent blows, they can jeopardise the correct
functioning of the probe;
- sterilise the spike before use;
- the maximum recommended thickness of the product
is 45mm;
- cleanliness of the spike determines good performance.
TO INSERT THE PROBE
- Insert the probe with the point as near as possible to
the heart of the product.
TO EXTRACT THE PROBE
- Heat the probe
see 7.2.5.
- Turn it.
- Extract it without tilting the spike.
7.1.1. CLOCK (only card AUX present, the hour recorder in permanent way)
With the machine turned off by the
button, it is possible to change the clock setting by keeping the
and
buttons pressed simultaneously for extended time.
• DISPLAY 1 indicates the year value
• DISPLAY 2 indicates the letters “YY”
By using the
and
buttons it is possible to change the values of the respectively:
year
month
day
hours
minutes
Use button
to confi rm the value, which is displayed thereafter. Press
button to exit.
7.2. OPERATIONAL CYCLES
7.2.0. SWITCHING ON
By pressing the
button the board turns on, no selection is visible in DISPLAY 1 (Fig.1), DISPLAY 2
indicates the cabinet temperature and the Stop symbol.
(Fig.1)
H max = 45mm
H 45mm
single point-probe