background image

23 - GB

 

 

7.2.3. BLAST CHILL OR SHOCK FREEZE PERSONALIZE CYCLE  ,  

 , 

 

 

It is possible to modify the breakdown/freezing cycle: 

    - 

timed 

    

- probe 

 , 

 

 

personalising them as required.

 

 

The breakdown or freezing cycle is divided into three phases where it is possible to modify the following  

  values:

 

 

 

 

IN ORDER TO MODIFY THE DATA IN NOT PERMANENT WAY

  Press 

the key relative to the cycle

 

 (+3 soft), or the key 

 (-18 soft) 

 

 

 then 

 and then press the key 

 for extended time (+3 hard).

 

 

 then 

 and then press the key 

 for extended time (-18 hard)

 

a- set cabinet temperature phase 1/2/3/4

 

 

Control displays (Fig. 8):

  SCREEN 

1- 

modifi able cell temperature 

 

 

SCREEN 2  - no signal (off)

 

 

SCREEN 3 – the number of the phase

(Fig.8)

   

The cell temperature symbol    fl ashes, by pressing the 

 or 

 the value of the set temperature  

 

 

is increased or decreased.

 

b- set pin temperature phase 1/2/3

 

 

With a further pressing the 

 the pin symbol fl ashes 

 , by pressing the 

 or 

 the  

 

 

value of the set pin temperature is increased or decreased.

 

c- set duration phase 1/2/3

 

 

With a further pressing the 

 the clock 

 symbol fl ashes, by pressing the 

 or 

 the  

 

 

value of the set duration is increased or decreased. 

 

 

 

Repeat the same procedure described for the later phases 2 and 3.

 

 

Phase 4 of conservation only involves setting the set temperature. To confi rm the settings of all the  

 

 

phases described, press the relevant key 

 or 

 for extended time.  

 

 

 

  Press 

the 

 

 button to start the cycle.

 

 

At the end of the cycle the machine moves into conservation phase automatically, see ch. 7.2.5.

 

 

 

 

The new sets of the personalised cycle will be lost when the machine is stopped with key 

 .

  

 

 

See tecincal manual

S _ _ = setpoint

BLAST CHILL OR SHOCK FREEZE

CONSERVATION

PHASE 1

PHASE 2

PHASE 3

PHASE 4

SET CABINET

S01

S04

S07

S10

SET CORE

S02

S05

S08

- -

SET TIME

S03

S06

S09

- -

 

 

IN ORDER TO MODIFY THE DATA IN PERMANENT WAY (see tecincal manual)

Summary of Contents for 700610

Page 1: ...HILLER SHOCK FREEZER page 15 GEBRAUCHS und WARTUNGSHANDBUCH GEBRAUCHS und WARTUNGSHANDBUCH ABKÜHL GEFRIERSCHRANK Seite 27 MANUEL d UTILISATION et d ENTRETIEN ARMOIRES MANUEL d UTILISATION et d ENTRETIEN ARMOIRES REFROIDISSEMENT ET DE CONGELATION RAPIDE page 39 MANUAL USO y MANTENIMIENTO MANUAL USO y MANTENIMIENTO CELDA ABATIDORA COGLADORA páge 51 IT IT GB GB DE DE FR FR ES ES 700610 PBF031AF A ...

Page 2: ...of 1 year from the date of invoice and consists of the free supply of spare parts which according to our final judgement are deemed to be defective It is the responsibility of the manufacturer to eliminate any faults and defects on condition that the machine has been correctly used in accor dance with the instructions provided in the manual During the guarantee period the customer will be responsi...

Page 3: ...s well as to waste disposal 3 OPERATION 3 1 APPLICATIONS PURPOSE FORESEEN AND UN FORESEEN USE AUTHORISED USE Our refigerators are agroindustrial machines EC regulation No 1935 2004 intended for foodstuffs The machines are designed with the appropriate equipment to guarantee the health and safety of the user APPLICATION OF THE BLAST CHILLER FREEZER The blast chiller freezer is a machine which rapid...

Page 4: ...rotections saftey de vices grills adhesive labels etc is prohibited 4 2 INSTRUCTIONS FOR EMERGENCY OPERATIONS IN THE CASE OF FIRE NOTE Do not use water in the case of fire Use CO2 fire extinguisher carbonic anhydride and cool the motor com partment area as quickly as possible 4 3 CLEANING THE MACHINE Before any cleaning operation disconnect the machine from the electrical power supply INITIAL INST...

Page 5: ...cated to the carrier immediately Damaged machines cannot be returned to the manufacturer under any circumstances unless notice is given and prior written authorisation is received DURING HANDLING DO NOT PUSH OR DRAG THE MACHINE SO AS TO AVOID IT FROM OVERTURNING OR ANY OF ITS PARTS BEING DAMAGED E G STABILITY FEET NEVER LEAN THE MACHINE ON THE SIDE OF THE DOOR 6 3 POSITIONING Position the machine ...

Page 6: ...ture of the evaporator probe is displayed PROBE HEATING Heating for extraction of food probe STERILISATION Start stop sterilisation process PROGRAMME Memory or recalls a blast chill shock freeze cycle on memory Description of the display and symbols DISPLAY 1 Displays temperature of the food probe or time DISPLAY 2 Displays temperature of the cabinet DISPLAY 3 Displays the operational phase in pro...

Page 7: ... AUX present the hour recorder in permanent way With the machine turned off by the button it is possible to change the clock setting by keeping the and buttons pressed simultaneously for extended time DISPLAY 1 indicates the year value DISPLAY 2 indicates the letters YY By using the and buttons it is possible to change the values of the respectively year month day hours minutes Use button to confi...

Page 8: ...dly or left in the holder provided the cycle is automatically converted to timer and DISPLAY 1 indicates the time to the end of the blast chill cycle Fig 4 The following symbols light up blast chill function temperature and blast chill sym Fig 4 bol DISPLAY 2 indicates the cabinet temperature and DISPLAY 3 the blast chill phase in progress If the temperature has not been reached through to the cor...

Page 9: ...hock freeze soft or hard temperature and By using the or buttons it is possible to change the cycle duration N B It is possible to set a duration either shorter or longer that 90 min for blast chill cycles or 240 min for shock freeze cycles Maximum limit 120 min for a 3 C cycle Maximum limit 300 min for a 18 C cycle Press the button to start the cycle Fig 7 By pressing button Fig 7 the temperature...

Page 10: ...hase 1 2 3 With a further pressing the the pin symbol flashes by pressing the or the value of the set pin temperature is increased or decreased c set duration phase 1 2 3 With a further pressing the the clock symbol flashes by pressing the or the value of the set duration is increased or decreased Repeat the same procedure described for the later phases 2 and 3 Phase 4 of conservation only involve...

Page 11: ...ng the button The machine sets itself on Stand by and the user is asked whether the programme is to be memorised or the button must be pressed once more Press the food probe heating button to facilitate extraction of the probe from the product The symbol lights up Food probe heating takes place only if the temperature of the probe is less than 5ºC 7 2 6 MEMORISING A BLAST CHILL SHOCK FREEZE PROGRA...

Page 12: ...manual Using parameter P72 see technical manual the language of the printer can be changed Time time elapsed Ti CABINET temperature Tc CORE temperature 7 6 ALARMS ERRORS 7 6 1 HIGH TEMPERATURE ALARM During the positive negative the alarm part when the temperature cabinet the values sets up Alarm code AL1 will flash on DISPLAY 1 The buzzer optional sounds but can be stopped by pressing a button Whe...

Page 13: ... convert the setting to time and the compressor check will be performed on the food probe instead of the cabinet probe A set temperature blast chill programme in progress with food probe inserted turns the compressor on and off on the basis of times memorised previously in blast chill or conversation phases 7 6 8 FOOD PROBE ALARM CONTACT TECHNICAL ASSISTANCE The food probe is used for reading core...

Reviews: