Installation Instructions
117623-117723
23 / 74
EN
• Be careful not to damage the rating plate and warning labels affixed to the
appliance.
• Remove all accessories, information materials, and plastic bags from the
appliance.
• Check if ventilation openings and fume extractor are not covered nor obstructed
in any way.
• Place the appliance in a way making the connections easily accessible, so that
they may be quickly disconnected if such a need arises.
•
Never place the appliance directly next to walls, low walls, division walls kitchen
furniture, or other surfaces made of flammable materials. Unconditionally
observe fire-fighting regulations in force.
• Maintain minimum clearance of at
least 50 mm at the rear and sides
between the appliance and walls or
other objects (Fig. 3).
• Leave a clearance of 500 mm
between the left side of the appliance
and other objects for the purpose of
facilitating installation and
maintenance of the appliance.
Fig. 3
• When it is not possible to maintain the recommended clearance, employ
appropriate protective measures (e.g. a foil made of a heat-resistant material)
that will ensure keeping the wall temperature within the safe range (up to 60°C).