Installation Instruction
(Translation)
HART Add-On Module
Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007
Technical data subject to change .
Revison A - 09/2016
EN 4/12
Type B7-A2Z0-0033 for tablet PC "Agile X"
ATEX Zone 2 and 22
II 3G Ex ic [ia Ga] IIC T4 Gc
II 3D Ex ic [ia Da] IIIB T135 °C Dc
EPS 15 ATEX 1 823 X
IECEx Zone 2 and Zone 22
Ex ic [ia Ga] IIC T4 Gc
Ex ic [ia Da] IIIB T135 °C Dc
IECEx EPS 15.0010X
NEC (USA/Canada)
Class I Division 2
Groups A, B, C and D
UL File E321557
Special conditions on the test certification EPS 15 ATEX 1 823 X
for type B7-A2Z0-0033
-
Maximum ambient temperature range: -20°C to +50°C.
-
External connectors shall never be used in hazardous areas. The battery shall never be
removed, changed or charged in hazardous areas. The RFID module shall never be mounted or
removed in hazardous areas. The flash (LED) shall never be used as a permanent light in
hazardous areas.
-
The apparatus shall be protected against mechanical impact, excessive UV-light and strong
charge generating processes.
-
In combination with Bartec accessory 03-9849-0130 (hand strap) the device is only suited for
gas group IIA.
-
It is allowed to connect the HART add on module to non certified HART circuits outside
hazardous areas. Um = 60 V shall never be exceeded. The user is responsible to meer this
condition.