Installation Instruction
(Translation)
HART Add-On Module
Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007
Technical data subject to change .
Revison A - 09/2016
EN 3/12
Marking, test certificate, and standards
Note:
Full information see "user manual" tablet PC.
Type 17-A1Z0-0005 for tablet PC "Agile X IS"
ATEX Zone 1
II 2G Ex ia [ia Ga] IIC T4 Gb
EPS 15 ATEX 1 069 X
IECEx Zone 1
Ex ia [ia Ga] IIC T4 Gb
IECEx EPS 15.0065X
NEC (USA/Canada)
Class I Div 1 Groups A, B, C, D T4
CSA 70045374
Type G7-A0Z0-0007 for tablet PC "Agile"
ATEX
II (2)G [ia Ga] IIC
EPS 15 ATEX 1 069 X
IECEx
[Ex ia Ga] IIC
IECEx EPS 15.0065X
NEC
[Ex ia Ga] II C
CSA 70045374
Special conditions on the test certification EPS 15 ATEX 1 069 X
for typs 17-A1Z0-0005 and G7-A0Z0-0007
-
Maximum ambient temperature range: -20 °C to +50 °C.
-
The HART add on modules shall be protected against strong charge generating processes.
-
It is allowed to connect the HART add on module to non certified HART circuits outside
hazardous areas.
Um = 60 V shall never be exceeded. The user is responsible to meet this
condition.