background image

Installation Instruction 

(Translation) 

HART Add-On Module 

Typs 17-A1Z0-0005 , B7-A2Z0-0033 and G7-A0Z0-0007 

 

Technical data subject to change . 

Revison A - 09/2016 

EN   6/12 

 

 

Introduction 

 

The intrinsically safe combination of the tablet PC system and the newly developed HART Add-On 

Module makes it possible to perform diagnostics, set parameters and manage field devices much 

more quickly and efficiently. The HART modem is used as an add-on module for the tablet PC 

system in its extension interface. Since the user is now able to switch safely between the Ex and 

non-Ex area, only one device is then needed for the wireless uploading or adjusting of the field 

devices distributed there, completely independently of the control system. 

Scope of delivery: 

-

 

1x HART Add-On Module 

-

 

2x Pan head screw M3x10 

-

 

2x Pan head screw M3x7 

-

 

2x Truss head screw M3x7 

-

 

2x Connection cable 

-

 

2x Test probes 

-

 

1x Installation instruction HART Add-On Module 

 

 

DANGER 

 

The extension interface of the tablet  PC  must always be sealed in a potentially explosive 

atmosphere!  There is a risk of explosion! 

 

Only remove or mount the cover of the extension module outside the potentially explosive 

atmosphere. 

 

Only assemble/dismantle the  HART Add-On Module  outside the  potentially explosive 

atmosphere. 

 

Risk of short circuiting if the screws supplied with delivery are not used. 

 

Carry out the correct assembly for the attachment. 

 

 

Use the screws supplied with delivery. All screws must be used to ensure the safe 

mechanical assembly of the HART Add-On Module on the tablet PC. 

Store the cover of the extension port safely. 

Summary of Contents for 17-A1Z0-0005

Page 1: ...HART Add On Module Installation Instruction...

Page 2: ...ocument No B1 A2Z0 7N0001 400570 Revision A Status 29 September 2016 Reservation Technical data subject to change without notice Changes errors and misprints may not be used as a basis for any claim f...

Page 3: ...Maintenance and Repairs The pertinent erection and operating provisions for electrical systems must be observed Repairs to explosion protected devices may only be performed by authorised personnel wit...

Page 4: ...are not permitted The generally applicable statutory regulations and other binding guidelines on occupational health and safety on accident prevention and on environmental protection must be complied...

Page 5: ...nada Class I Div 1 Groups A B C D T4 CSA 70045374 Type G7 A0Z0 0007 for tablet PC Agile ATEX II 2 G ia Ga IIC EPS 15 ATEX 1 069 X IECEx Ex ia Ga IIC IECEx EPS 15 0065X NEC Ex ia Ga II C CSA 70045374 S...

Page 6: ...B7 A2Z0 0033 Maximum ambient temperature range 20 C to 50 C External connectors shall never be used in hazardous areas The battery shall never be removed changed or charged in hazardous areas The RFID...

Page 7: ...DC 30 V II 130 mA PI 1 W U0 DC 3 V I0 10 mA P0 5 mW Um DC 60 V max cable length 1 8 m Size weight x length x height 125 mm x 125 mm x 24 mm Weight 200 g Protection class IEC 60529 Mounted on tablet P...

Page 8: ...etely independently of the control system Scope of delivery 1x HART Add On Module 2x Pan head screw M3x10 2x Pan head screw M3x7 2x Truss head screw M3x7 2x Connection cable 2x Test probes 1x Installa...

Page 9: ...he purpose that they have been tested and certificated by BARTEC Avoid data losses Do not just switch the tablet PC using the ON OFF switch 1 Shut the tablet PC down using the operating system 2 Place...

Page 10: ...ing and assembly 9 Switch the tablet PC on using the ON OFF button Optional Attach hand strap Material No 03 9849 0130 10 Losen the top screw that holds the HART Add On Module in place 11 Place the ha...

Page 11: ...ng the HART Add On Module 1 Click on Hottab on the start screen to start the application 2 Click in the menu on the option Device ON OFF 3 Select Ext Module to active the extension interface orange ON...

Page 12: ...ort is not listed in the tablet PC s system image a new CP2109 USB to UART Bridge Controller device will appear under Other devices in the device manager once the HART Add On Module has been mounted 2...

Page 13: ...to change Revison A 09 2016 EN 11 12 5 The User Account Control UAC window opens 6 Start installation by clicking on Yes 7 Continue installation in the CP210x USB to UART Bridge Driver Installer wind...

Page 14: ...evison A 09 2016 EN 12 12 9 The The Drivers were successfully installed on this computer message appears in the window Complete installation by clicking on Finish 10 Once the driver has been installed...

Page 15: ......

Page 16: ...0 7N0001 09 2016 Automation 400570 Your partner for safety technology Challenge us BARTEC GmbH Germany Phone 49 7931 597 0 Fax 49 7931 597 119 Max Eyth Str 16 97980 Bad Mergentheim info bartec de www...

Reviews: