Safety Instructions 

The  Ex  d  control  station  may  be  used  only 
within  the  specified  temperature  class  and  the 
temperature  range  indicated  for  it  (see  type 
label).  
The Ex d control station is not suitable for use 
in  Zone  0.  The  Ex  d  control  station  may  be 
operated only if it is clean and not damaged in 
any way. 
Utilization  in  areas  other  than  those  specified 
and the modifications of the product by anyone 
other  than  the  manufacturer  are  not  permitted 
and  will  exempt  BARTEC  from  liability  for 
defects and any further liability. 
The  generally  applicable  statutory  rules  and 
other  binding  directives  relating  to  workplace 
safety,  accident  prevention  and  environmental 
protection must be observed. 
When  using  electrical  systems,  the  relevant 
regulations  on  installation  and  operation  must 
be  complied  with.  The  specifications  on  the 
type label must be observed. 
Observe  the  applicable  laws  and  directives 
when  commissioning  or  restarting  operation. 
Always  follow  the  safety  instructions  on  the 
operating equipment.  
 

Marking 

Particularly  important  points  in  these  instruc-
tions are marked with a symbol: 
 

 

DANGER  indicates  a  hazardous  situation
which,  if  not  avoided,  will  result  in  death  or 
serious injury. 

 

WARNING  indicates  a  hazardous  situation 
which,  if  not  avoided,  could  result  in  death  or 
serious injury. 

 

CAUTION  indicates  a  hazardous  situation
which,  if  not  avoided,  could  result  in  minor  or 
moderate injury.  

 

NOTICE is used to address practices not 
related to personal injury. 
 

 

Note 

Important  instructions  and  information  on 
effective,  economical  and  environmentally 
compatible handling.

 

 

 

Standards conformed to 

EN 60079-0:2009 
EN 60079-1:2007 
EN 60079-7:2007 
EN 60079-11:2007 
as well as 
EN 60439-2:2000 + A1:2005 
EN 62208:2003 
EN 60445:2010 
EN 60529:1991 + A1:2000 
 

 

Note 

For  the  standards  for  the  installed  parts,  see 
the  separate  documentation  for  the  built-in 
component.  
 

Assembly / Disassembly 

 

Death or serious injury due to incorrect 
assembly. 

 

Metallic  enclosures  in  hazardous  areas 
require  equipotential  bonding  with  at  least 
4 mm².  The  connections  must  be  secured 
against self loosening. 

 

Risk of injury due to incorrect proceedings. 

 

Only  authorized  and  qualified  personnel 
who  are  authorized  and  trained  to  assem-
ble  electrical  components  in  hazardous 
(potentially explosive) areas may do any of 
the assembly, disassembly, installation and 
commissioning work. 

 

The  relevant  installation  and  operating 
regulations must be observed when setting 
up  or  operating  explosion-proof  electric 
systems. 

 

Always disconnect the Ex d control station
from  voltage  before  assembling  /  disas-
sembling. 

 

Follow the components mounting instructi-
ons/operating instructions. 

 
Check when assembling: 

 

Mount the Ex d control station with resis-
tance  to  torsion  on  an  even  supporting 
surface. Fixing dimensions and the  holes 
to be made, see drawings on page 4. 

 

Secure  the  connections  against  self 
loosening. 

 

 

Note 

For  enclosures  set  up  outdoors  it  may  be 
necessary  to  implement  measures  to  ensure 
operation  in  accordance  with  the  intended 
purpose (e.g. shelter from the rain or an outer 
enclosure with a suitable protection class). 

 

 

 

Death or serious injury due to a potentially 
explosive atmosphere. 

 

Never open the Ex d control station in the 
presence  of  a  potentially  explosive  atmos-
phere.  

 

Always disconnect the Ex d control station
from voltage before opening it. 

 
Pay  attention  at  the  opening/closing  of  flame-
proof enclosures: 

 

Disconnect  the  Ex  d  control  station  from 
voltage. 

 

Loosen the screws in the cover cam until 
they  are  no  longer  engaged  with  the 
threads. 

 

Unscrew the lid to the left and make sure 
it can’t fall off. 

 

Close  the  enclosure  again  in  reverse 
order. 

 

Installation 

 

Death or serious injury due to improper use. 

 

Extensions  or  modifications  to  the  Ex  d 
control  station  are  only  permissible  if  the 
manufacturer’s approval is obtained first. 

 

The IEC/EN60079-14 must be observed. 

 
Check when installing: 

 

When  connecting  cables  and  conductors 
to  operating  equipment  with  the  “Ex  e” 
type  of  protection,  use  Ex-certified  cable 
entries that are suitable for the respective 
types  of  cables  and  conductors.  They 
must conform to the “Ex e” type of protec-
tion  and  have  a  suitable  sealing  element 
to maintain the control station’s protection 
class. 

 

Connect  metallic  cable  entries  to  the 
earthing system.  

 

Seal  unused  cable  entry  holes  with  Ex-
certified stopping plugs. 

 

When  connecting  directly  to  the  flame-
proof  enclosure,  use  Ex-certified  entries 
that are suitable for the enclosure capaci-
ty, the gas sub-group and the conductor. 

 
Take care when connecting conductors: 

 

Always  use  suitable  crimping  tools  when 
crimping the wire-end ferrules to ensure a 
consistent quality of pressing each time.  

 

Take  care  to  establish  the  connection 
properly.  

 

Tighten all terminal points (including those 
not in use) securely. 

 