60-26
®
SERVICE- HYD PUMP T6, T7 VANE
(continued...)
Bolt
Port Plate- Rear
Rotor
Port Plate- Pressure
Cam Ring
Dowel Pins
Pin
Vane
Back-Up Ring
Seals
The seal
usually stays in
the rear cap.
!
Fig-3
General Cartridge Assembly (see Fig-3)
2. PUMP SERVICE & REPAIR
2.1 Pump Disassembly (Double Vane Pump steps shown, see Fig-2 for reference)
1.
2.
3.
After pump is removed from machine,
place on a stable work surface.
Loosen and remove end cover cap
screws.
Remove the end cap (P2 cartridge will
come with it).
(Fig-4)
Fig-4
06/05/2019
Updated
SERVICE
Summary of Contents for 830B
Page 4: ...THIS PAGE INTENTIONALLY BLANK SUPERIOR WI USA www barko com...
Page 42: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 48: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 50: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 54: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 60: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 70: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 94: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 102: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 104: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 114: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 118: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 124: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 133: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 134: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 138: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 172: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 181: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 182: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 184: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 194: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 207: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 208: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 210: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 215: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 216: ...THIS PAGE LEFT INTENTIONALLY BLANK...
Page 217: ...THIS PAGE LEFT INTENTIONALLY BLANK...